Interobserver and intraobserver reliability of skull base angles measured on magnetic resonance images.

作者信息

Kizilgoz Volkan, Aydin Sonay, Aydemir Huseyin, Keles Papatya, Kantarci Mecit

机构信息

Department of Radiology, Erzincan Binali Yıldırım University, Faculty of Medicine, Erzincan 24000, Türkiye.

Department of Anatomy, University of Health Sciences, Hamidiye Faculty of Medicine, İstanbul 34674, Türkiye.

出版信息

World J Clin Cases. 2024 Dec 6;12(34):6687-6695. doi: 10.12998/wjcc.v12.i34.6687.

Abstract

BACKGROUND

Determination of platybasia and basilar kyphosis are significant parts of routine cranial magnetic resonance (MR) interpretations. These situations may explain a patient's symptoms or may be associated with other anomalies.

AIM

To indicate the interobserver and intraobserver reliability of the skull base angles (SBA) (Koenigsberg standard) and modified SBA (mSBA) measurement techniques.

METHODS

In total, 391 patients who had undergone cranial MR imaging were re-assessed regarding the SBA measurements. The SBA and mSBA techniques were used on MR images. Two reviewers independently measured the same angles twice within a 15-day interval, using different monitors. Intraclass correlation coefficient (ICC) was calculated to reveal the intraobserver and interobserver agreements.

RESULTS

There was an excellent agreement between reviewers regarding both angle measurements (ICC was 0.998 for SBA and mSBA). Excellent agreement levels were also observed for intraobserver measurements. ICC was 0.998 for SBA and 0.999 for mSBA for reviewer 1. ICC was 0.997 for SBA and 0.999 for mSBA according to the measurement results of reviewer 2. Higher SBA and mSBA values were observed for females compared to males. There was no correlation between SBA and age for SBA. However, a negative and low-level correlation was observed between mSBA values and age for both reviewers.

CONCLUSION

SBA and mSBA measurements indicated excellent agreement regarding interobserver and intraobserver differences. The study results showed that SBA angles were reliable measurement techniques to be used on MR images.

摘要

背景

扁平颅底和基底后凸的判定是常规头颅磁共振成像(MR)解读的重要部分。这些情况可能解释患者的症状,或与其他异常相关。

目的

指出颅底角(SBA)(柯尼斯堡标准)和改良SBA(mSBA)测量技术在观察者间和观察者内的可靠性。

方法

对总共391例接受过头颅MR成像的患者进行了SBA测量的重新评估。在MR图像上使用SBA和mSBA技术。两名观察者在15天内使用不同显示器独立测量相同角度两次。计算组内相关系数(ICC)以揭示观察者内和观察者间的一致性。

结果

观察者之间在两种角度测量方面均具有极好的一致性(SBA和mSBA的ICC均为0.998)。观察者内测量也观察到极好的一致性水平。观察者1的SBA的ICC为0.998,mSBA的ICC为0.999。根据观察者2的测量结果,SBA的ICC为0.997,mSBA的ICC为0.999。女性的SBA和mSBA值高于男性。SBA与年龄之间无相关性。然而,两位观察者的mSBA值与年龄之间均观察到负向且低水平的相关性。

结论

SBA和mSBA测量在观察者间和观察者内差异方面显示出极好的一致性。研究结果表明,SBA角度是用于MR图像的可靠测量技术。