In forensic laboratories, analytical investigations of gunshot residues (GSRs) are usually conducted by scanning electron microscopy (SEM) in combination with energy dispersive X-ray microanalysis. If GSRs are covered with bloodstains, SEM cannot detect them. In this study, an inductively coupled plasma mass spectrometry method is proposed to solve this problem. Results show that bloodstains did not interfere with GSRs and low-level elements are detected. Qualitative and quantitative analyses of Sn, Sb, Ba, and Pb elements in GSRs are also carried out. Different pretreatment methods are adopted according to the characteristics of different samples. Our investigations suggest that the proposed method has the advantages of low detection limit and high sensitivity and it can be very important in expert testimony.

KEY POINTS

GSRs with bloodstains could be successfully detected ICP-MS and bloodstains did not interfere in GSRs analysis.The best pretreatment method for incident bullet holes with bloodstains was microwave digestion.The best pretreatment method for the region around the bullet hole and the shooter's hand with bloodstains was ultrasonic vibration.For the same shooting distance, GSRs collected from the cloth and the shooter's hand with type 95-1 rifle were higher than that of type 92 pistol.

摘要

未标注

在法医实验室中,枪击残留物(GSR)的分析研究通常通过扫描电子显微镜(SEM)结合能量色散X射线微分析来进行。如果GSR被血迹覆盖,SEM就无法检测到它们。在本研究中,提出了一种电感耦合等离子体质谱法来解决这个问题。结果表明,血迹不会干扰GSR,并且能够检测到低含量元素。还对GSR中的锡、锑、钡和铅元素进行了定性和定量分析。根据不同样品的特点采用了不同的预处理方法。我们的研究表明,所提出的方法具有检测限低和灵敏度高的优点,并且在专家证词中可能非常重要。

关键点

带有血迹的GSR能够通过电感耦合等离子体质谱成功检测,并且血迹不会干扰GSR分析。对于带有血迹的入射弹孔,最佳预处理方法是微波消解。对于带有血迹的弹孔周围区域和射手的手,最佳预处理方法是超声振动。在相同射击距离下,用95-1式步枪从布料和射手手上收集到的GSR高于92式手枪的。