Suppr超能文献

新型Castor分支型主动脉弓覆膜支架系统在欧洲的多中心初始应用:中期结果研究

Initial Multicenter Experience With the New Castor Arch Branched Device in Europe: A Middle-term Results Study.

作者信息

Żołnierczuk Michał, Rynio Paweł, Rybicka Anita, Głowiński Jerzy, Milnerowicz Artur, Pormanczuk Kornel, Kostka Andrzej, Oszkinis Grzegorz, Hobot Jacek, Gutowski Piotr, Kazimierczak Arkadiusz

机构信息

Department of Vascular Surgery, General Surgery and Angiology, Pomeranian Medical University, Szczecin, Poland.

Department of Nursing, Faculty of Health Sciences, Pomeranian Medical University in Szczecin, Szczecin, Poland.

出版信息

J Endovasc Ther. 2024 Dec 12:15266028241304307. doi: 10.1177/15266028241304307.

Abstract

BACKGROUND

Published reports demonstrate that the use of Castor stent-graft is a promising treatment of aortic pathologies with the need to land in zone 2. However, there is a lack of publications on the medium-term results of Castor in the European population. This research evaluates the mid-term results of the Castor stent-graft in several Polish centers for the treatment of aortic pathologies and enriches the current knowledge of Castor stent-grafts.

MATERIAL AND METHODS

Twenty-one patients from 5 polish vascular surgery centers in subacute phase of type B aortic dissection (TBAD) with at least 1 classic risk factor of aneurysmatic degeneration, thoracic aortic aneurysms (TAAs) exceeding 5.5 cm, subacute phase of intramural hematomas (IMHs) and penetrating aortic ulcerations (PAUs) with at least 1 indication to endovascular treatment. Structure of the aortic arch and factors of aneurysmal degeneration for TBAD were highlighted. Early complications, long-term complications, and reinterventions after Castor device implantation are reported in the study.

RESULTS

Twenty (95.24%) patients survived, of which a technical success involving implantation of the Castor device in the correct location with a patent branch for the left subclavian artery, and no endoleaks were noted in 19 (90.48%) patients. After the procedure, there were 2 (9.52%) cases of type I endoleak (in which technical success was not achieved) and 2 (9.52%) cases of bird beak. In addition, 1 case of access site hematoma, 1 case of pseudoaneurysm, and 1 case of access iliac artery rupture requiring implantation of a Viabahn device were observed. During the follow-up period (mean 14 months; range = 1-40 months), 1 patient required reintervention due to type I endoleak and 1 patient due to left subclavian artery (LSA) branch thrombosis. Two patients required subsequent branched endovascular aortic repair procedure due to unfavorable remodeling and fast aneurysm formation in visceral aorta, regardless of Castor results.

CONCLUSION

The Castor device is an easy-to-use stent-graft with good medium-term results. It is an excellent option in cases requiring LSA revascularization during TEVAR.

CLINICAL IMPACT

In this study, we investigate the medium-term results of the Castor stent graft in patients with type B aortic dissection, thoracic aortic aneurysm, intramural hematoma and penetrating aortic ulceration. The medium-term results of treatment with the Castor device are not yet well studied. Currently, there are only a small number of publications on the safety, complications and success of Castor device implantation.

摘要

背景

已发表的报告表明,使用Castor支架型人工血管是治疗需要锚定在2区的主动脉病变的一种有前景的方法。然而,关于Castor在欧洲人群中的中期结果的出版物较少。本研究评估了Castor支架型人工血管在波兰几个中心治疗主动脉病变的中期结果,丰富了目前对Castor支架型人工血管的认识。

材料与方法

来自波兰5个血管外科中心的21例患者,处于B型主动脉夹层(TBAD)亚急性期,伴有至少1个动脉瘤样退变的典型危险因素、直径超过5.5 cm的胸主动脉瘤(TAA)、壁内血肿(IMH)亚急性期以及穿透性主动脉溃疡(PAU)且至少有1个血管内治疗指征。重点关注了TBAD的主动脉弓结构和动脉瘤样退变因素。研究报告了Castor装置植入后的早期并发症、长期并发症和再次干预情况。

结果

20例(95.24%)患者存活,其中19例(90.48%)患者在正确位置成功植入Castor装置且左锁骨下动脉分支通畅,未发现内漏。术后,有2例(9.52%)I型内漏(未实现技术成功)和2例(9.52%)鸟嘴样病变。此外,观察到1例穿刺部位血肿、1例假性动脉瘤和1例髂动脉穿刺处破裂需要植入Viabahn装置。在随访期间(平均14个月;范围 = 1 - 40个月),1例患者因I型内漏需要再次干预,1例患者因左锁骨下动脉(LSA)分支血栓形成需要再次干预。2例患者因内脏主动脉重塑不良和动脉瘤快速形成需要后续进行分支型血管内主动脉修复手术,与Castor治疗结果无关。

结论

Castor装置是一种易于使用的支架型人工血管,中期结果良好。在TEVAR期间需要LSA血运重建的情况下,它是一个极佳的选择。

临床影响

在本研究中,我们调查了Castor支架型人工血管治疗B型主动脉夹层、胸主动脉瘤、壁内血肿和穿透性主动脉溃疡患者的中期结果。Castor装置治疗的中期结果尚未得到充分研究。目前,关于Castor装置植入的安全性、并发症和成功率的出版物较少。