Wu Ruibin, Jiang Yuzhen, Zhu Yinghui, Wang Wei, Huang Peizhu, Dong Xiaoqing, Suhail Shaikh Muhammad
Chaozhou People's Hospital, Chaozhou, Guangdong Province, China.
Hanshan Normal University, Chaozhou, Guangdong Province, China.
J Int Med Res. 2024 Dec;52(12):3000605241303190. doi: 10.1177/03000605241303190.
This study investigated a method for assessing movement patterns in patients with functionally limited temporomandibular disorders using minimal equipment. The aim was to enable clinicians to better understand temporomandibular joint function, support treatment decision-making, and provide data for documenting disease progression.
This retrospective, observational study included 45 patients with functionally limited temporomandibular disorders (Group A) and 40 healthy volunteers (Group B). Video data of temporomandibular joint movements were recorded. Measurements, including maximum mouth opening distance, maximum offset distance, maximum offset angle, direction of offset, and fluctuation graphs of offset angle and distance, were obtained using manual methods and an automatic measurement program. The results were statistically analyzed.
Statistically significant differences were observed between patients and the control group in the manually measured mouth opening distance and offset distance, as well as in the automatically measured offset distance and offset angle.
Automated testing methods can effectively assess the motor function of functionally limited temporomandibular joints, providing more objective, data-driven, and graphical testing indexes. Further research is warranted to explore their practical significance.
本研究探讨了一种使用最少设备评估功能受限颞下颌关节紊乱症患者运动模式的方法。目的是使临床医生能够更好地了解颞下颌关节功能,支持治疗决策,并为记录疾病进展提供数据。
本回顾性观察研究纳入了45例功能受限颞下颌关节紊乱症患者(A组)和40名健康志愿者(B组)。记录颞下颌关节运动的视频数据。使用手动方法和自动测量程序获得测量值,包括最大开口距离、最大偏移距离、最大偏移角度、偏移方向以及偏移角度和距离的波动图。对结果进行统计学分析。
在手动测量的开口距离和偏移距离以及自动测量 的偏移距离和偏移角度方面,患者与对照组之间存在统计学上的显著差异。
自动化测试方法可以有效评估功能受限颞下颌关节的运动功能,提供更客观、数据驱动和图形化的测试指标。有必要进一步研究以探索其实际意义。