Hussain Zahid, Ortiz Jesús D, Hosseini Seyed Arman, Benmokrane Brahim, Nanni Antonio
Civil and Architectural Engineering Department, University of Miami, Coral Gables, FL 33146 USA.
Department of Civil and Building Engineering, University of Sherbrooke, Sherbrooke, QC J1K2R1 Canada.
Int J Concr Struct Mater. 2024;18(1):87. doi: 10.1186/s40069-024-00729-1. Epub 2024 Dec 12.
The current provisions for development length in the ACI 440.11 code disregard the confinement effect provided by stirrups on the bond strength of longitudinal bars and require splice lengths that pose implementation challenges. Given the significant improvement in GFRP material properties, this study investigated the bond strength of sand-coated GFRP bars and proposed a new factor to include the effect of stirrup confinement on the bond-strength provisions. The experimental program involved 16 GFRP-reinforced concrete (RC) beams having a width of 300 mm, and depth 440 mm, consisting of two repetitions for every configuration, subjected to four-point loading. The test parameters comprised lap-splice length and stirrup spacing in the lap-spliced zone. Out of 16 GFRP-RC beams, two beams were reinforced with two M16 (No. 5) continuous bars and six with varying lap-splice lengths [i.e., 40, 60, and 80 bar diameters (d)] without confining stirrups. To evaluate the effect of confining stirrups, eight beams were reinforced with two M16 (No. 5) lap-spliced longitudinal bars (i.e., 40 and 60 d) and M13 (No. 4) stirrups spaced at 100 mm (4 in.) and 200 mm (8 in.) center-to-center. Based on experimental results, stirrup confinement clearly increased the bond strength, reduced longitudinal bar slippage, and increased splitting stress. The beams with a splice length of 60 d and stirrups on 100 mm (4 in.) centers achieved 57% higher capacity than those with the same lap-splice length but without stirrups. Further, the ACI 440.11 equation overestimated the bond strength of sand-coated GFRP bars but yielded conservative results with closely spaced stirrups. CSA S6:25 predicted bond-strength values that were close to the experimental results compared to CSA S6:19, and CSA S806:12.
美国混凝土学会(ACI)440.11规范中当前关于发展长度的规定忽略了箍筋对纵向钢筋粘结强度的约束作用,并且所要求的搭接长度在实际应用中存在挑战。鉴于玻璃纤维增强塑料(GFRP)材料性能有显著提升,本研究对砂涂层GFRP筋的粘结强度进行了研究,并提出了一个新的系数,以纳入箍筋约束对粘结强度规定的影响。试验方案包括16根GFRP增强混凝土(RC)梁,梁宽300毫米,梁高440毫米,每种配置重复两次,采用四点加载。试验参数包括搭接长度和搭接区箍筋间距。在16根GFRP-RC梁中,两根梁采用两根M16(5号)连续钢筋配筋,六根梁采用不同的搭接长度[即40、60和80倍钢筋直径(d)]且无约束箍筋。为评估约束箍筋的效果,八根梁采用两根M16(5号)搭接的纵向钢筋(即40d和60d)以及间距为100毫米(4英寸)和200毫米(8英寸)的M13(4号)箍筋,箍筋中心距中心布置。基于试验结果,箍筋约束显著提高了粘结强度,减少了纵向钢筋滑移,并提高了劈裂应力。搭接长度为60d且箍筋间距为100毫米(4英寸)中心距的梁比相同搭接长度但无箍筋的梁承载力高57%。此外,ACI 440.11公式高估了砂涂层GFRP筋的粘结强度,但在箍筋间距较小时得出了保守结果。与CSA S6:19和CSA S806:12相比,CSA S6:25预测的粘结强度值更接近试验结果。