Suppr超能文献

二维斑点追踪超声心动图在评估小胎儿心功能中的价值。

Value of two-dimensional speckle-tracking echocardiography in evaluation of cardiac function in small fetuses.

作者信息

Zhang Wen, Zhang Bo, Wu Ting, Li Yueping, Qi Xiaoying, Tian Yu, Chen Jiao, Luo Hong

机构信息

Department of Ultrasonic Medicine, West China Second Hospital of Sichuan University, Chengdu, China.

Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu, China.

出版信息

Quant Imaging Med Surg. 2024 Dec 5;14(12):8155-8166. doi: 10.21037/qims-24-794. Epub 2024 Oct 24.

Abstract

BACKGROUND

Small fetuses include constitutional small for gestational age (SGA) and fetal growth-restricted (FGR) fetuses. Various adverse intrauterine environments can lead to FGR which has higher risk of abnormal perinatal outcome. The fetal heart is very sensitive to the effects of a negative intrauterine environment. Therefore, we used two-dimensional speckle-tracking echocardiography (2D-STE) to evaluate heart function and find more sensitive indicators of pregnancy outcomes of small fetuses.

METHODS

This prospective cohort study was performed at West China Second Hospital of Sichuan University between July 2023 and December 2023. We prospectively enrolled small fetuses with an estimated weight or abdominal circumference below the 10th percentile for gestational age and controls matched for gestational age. 2D-STE was performed to obtain information on left ventricular function systolic function and strain parameters, including ejection fraction (EF), myocardial global circumferential strain (myoGCS), myocardial global longitudinal strain (myoGLS), endocardial global circumferential strain (endoGCS), endocardial global longitudinal strain (endoGLS), and global radial strain (GRS). The baseline characteristics and various cardiac parameters were compared between the groups. Then, we analyzed the predictive performance of cardiac parameters, and pulsatility index of umbilical artery and middle cerebral artery (UA-PI, MCA-PI) for adverse pregnancy outcomes.

RESULTS

A total of 61 small fetuses and 34 gestational age-matched control fetuses were studied ultimately. The value of EF, myoGCS, myoGLS,endoGCS, endoGLS, and GRS were 44.85±10.04, -11.89±4.24, -9.26±4.24, -22.68±6.24, -13.53±6.67, and 24.98±12.44, respectively, in the FGR group, the absolute values of which were significantly lower than in the SGA group (53.28±6.70, -14.42±4.31, -12.63±4.11, -27.29±7.25, -17.71±5.58, and 33.37±9.33, respectively) and the control group (55.46±6.94, -14.93±4.77, -16.15±3.84, -27.69±6.46, -20.55±4.42, and 36.87±12.69, respectively) (P<0.05). The absolute myoGLS and endoGLS values were significantly lower in the SGA group than in the control group (P<0.05). Combination of endoGLS and UA-PI could represent a new predictor to predict the adverse pregnancy outcomes, and the receiver operating characteristic (ROC) curve exhibited a considerably higher area under the curve (AUC) than either one alone (AUC of 0.75 0.69 and 0.61, respectively).

CONCLUSIONS

The layer-specific strain technique in 2D-STE is a sensitive tool for evaluation of left ventricular myocardial deformation in the heart of small fetuses, and can be used to identify the changes of cardiac function between FGR and SGA. Moreover, the combination of endoGLS and UA-PI as a new parameter may have better performance in predicting pregnancy outcome of small fetuses.

摘要

背景

小胎儿包括小于胎龄儿(SGA)和胎儿生长受限(FGR)胎儿。各种不良的宫内环境可导致FGR,其围产期异常结局的风险更高。胎儿心脏对不良宫内环境的影响非常敏感。因此,我们使用二维斑点追踪超声心动图(2D-STE)来评估心脏功能,并寻找小胎儿妊娠结局更敏感的指标。

方法

这项前瞻性队列研究于2023年7月至2023年12月在四川大学华西第二医院进行。我们前瞻性纳入了估计体重或腹围低于胎龄第10百分位数的小胎儿以及与之匹配的胎龄对照组。进行2D-STE以获取左心室功能收缩功能和应变参数的信息,包括射血分数(EF)、心肌整体圆周应变(myoGCS)、心肌整体纵向应变(myoGLS)、心内膜整体圆周应变(endoGCS)、心内膜整体纵向应变(endoGLS)和整体径向应变(GRS)。比较两组之间的基线特征和各种心脏参数。然后,我们分析了心脏参数、脐动脉和大脑中动脉搏动指数(UA-PI、MCA-PI)对不良妊娠结局的预测性能。

结果

最终共研究了61例小胎儿和34例胎龄匹配的对照胎儿。FGR组中EF、myoGCS、myoGLS、endoGCS、endoGLS和GRS的值分别为44.85±10.04、-11.89±4.24、-9.26±4.24、-22.68±6.24、-13.53±6.67和24.98±12.44,其绝对值显著低于SGA组(分别为53.28±6.70、-14.42±4.31、-12.63±4.11、-27.29±7.25、-17.71±5.58和33.37±9.33)和对照组(分别为55.46±6.94、-14.93±4.77、-16.15±3.84、-27.69±6.46、-20.55±4.42和36.87±12.69)(P<0.05)。SGA组中myoGLS和endoGLS的绝对值显著低于对照组(P<0.05)。endoGLS和UA-PI的组合可作为预测不良妊娠结局的新指标,其受试者操作特征(ROC)曲线下面积(AUC)显著高于单独使用任何一个指标(分别为0.75、0.69和0.61)。

结论

2D-STE中的层特异性应变技术是评估小胎儿心脏左心室心肌变形的敏感工具,可用于识别FGR和SGA之间的心脏功能变化。此外,endoGLS和UA-PI的组合作为一个新参数在预测小胎儿妊娠结局方面可能具有更好的性能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5637/11651951/8149e7744a3b/qims-14-12-8155-f1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验