Am J Physiol. 1985 Jan;248(1 Pt 2):H132-42. doi: 10.1152/ajpheart.1985.248.1.H132.
Experiments were conducted in open-chest dogs in which ascending aortic blood flow (Q) was measured with an electromagnetic flow probe, and pressure was measured in the left ventricle (LV) and ascending aorta. The aorta just distal to the flow probe was occluded suddenly, causing the aortic bulb (AB) to be the only part of the arterial system to be in communication with the LV during clamped beats. Pressure and flow data from preocclusion, occlusion, and occlusion-release periods were analyzed to assess AB compliance (CAB) and the longitudinal impedance properties of inertance (LVO) and resistance (RVO) in the AB-aortic orifice region. In five dogs (avg wt 24.2 kg), the mean and range of values were as follows: CAB = 45 (31-55) X 10(-4) cm5/dyn; LVO = 1.86 (0.76-2.88) dyn X s2 X cm-5, RVO = 4.07 (0.66-8.55) dyn X s X cm-5. The volume-accommodating actions of CAB caused actual LV outflow to be characteristically different from Q and aortic-clamped beats to be nonisovolumic. Actions of the AB were found to be important in the estimation of arterial characteristic impedance as a component of LV afterload and in the estimation of the LV pump properties of time-varying elastance and internal resistance.
实验在开胸犬身上进行,用电磁流量探头测量升主动脉血流量(Q),并测量左心室(LV)和升主动脉的压力。在流量探头远端的主动脉突然被阻断,导致在夹闭搏动期间动脉球(AB)成为动脉系统中与左心室相通的唯一部分。分析阻断前、阻断和阻断释放期的压力和流量数据,以评估AB顺应性(CAB)以及AB - 主动脉口区域的惯性(LVO)和阻力(RVO)的纵向阻抗特性。在5只犬(平均体重24.2千克)中,数值的均值和范围如下:CAB = 45(31 - 55)×10⁻⁴ cm⁵/dyn;LVO = 1.86(0.76 - 2.88)dyn·s²·cm⁻⁵,RVO = 4.07(0.66 - 8.55)dyn·s·cm⁻⁵。CAB的容积容纳作用导致实际左心室流出量与Q有显著差异,且主动脉夹闭搏动为非等容搏动。发现AB的作用在估计作为左心室后负荷组成部分的动脉特征阻抗以及估计左心室时变弹性和内阻的泵功能方面很重要。