Raval B, Steinberg R, Rauschkolb E
J Comput Tomogr. 1985 Jan;9(1):9-11. doi: 10.1016/0149-936x(85)90043-8.
A method is described for obtaining consistently high-quality images during nonneurologic computed tomography of the severely ill and uncooperative patient using a neuromuscular blocker to induce apnea. Careful control of respiration during data acquisition eliminates motion artifacts.
描述了一种在对重症且不合作的患者进行非神经科计算机断层扫描时,使用神经肌肉阻滞剂诱导呼吸暂停以持续获得高质量图像的方法。在数据采集期间仔细控制呼吸可消除运动伪影。