Suppr超能文献

单纯近视散光及其轴位对假晶状体眼泰国字母近视力的影响。

Effect of Simple Myopic Astigmatism and Its Axis on Near Visual Performance for Thai Alphabet in Pseudophakic Eyes.

作者信息

Pakviwat Pakpum, Moollaong Chureeporn, Borvonshivabhumi Sasinut, Roongpoovapatr Vatookarn

机构信息

Department of Ophthalmology, Mettapracharak (Wat Rai Khing) Hospital, Nakhon Pathom, Thailand.

出版信息

Clin Ophthalmol. 2024 Dec 17;18:3815-3823. doi: 10.2147/OPTH.S485353. eCollection 2024.

Abstract

BACKGROUND

Refractive target of low simple myopic astigmatism allows increased depth-of-focus and near visual performance in monofocal intraocular lens (IOL) implants. This study investigated the effect of astigmatism and its axis on distance and near visual acuity (VA), and near visual performance for the Thai alphabet using the Thai MNREAD chart.

DESIGN

Investigational simulation.

METHODS

Distance (6.0 m) VA, near (40 cm) VA and near visual performance (maximum reading speed [MRS], threshold print size [TPS] and reading acuity [RA]), were assessed by the Thai MNREAD chart monocularly in 31 pseudophakic eyes (62.8 ± 8.55 years). Six refractive conditions were simulated using trial lenses: ±0.00 DS [in-focus at distance], +1.00 × 90 [ATR (Against-the-Rule)], +2.00 × 90 [ATR], +1.00 × 180 [WTR (With-the-Rule)], +2.00 × 180 [WTR], and +3.00 DS [in-focus at near].

RESULTS

Distance VA was degraded by spherical and astigmatic defocus compared with +0.00 DS [in-focus (distance)] (p < 0.001). No significant difference in distance VA was found between ATR and WTR astigmatism at the same magnitude. Near VA was better with +3.00 DS (p-value < 0.001) compared with other refractive conditions. Near visual performance (threshold print size [TPS]) was significantly better in ATR compared with WTR astigmatism (p <0.001 for both +1.00 DC and 2.00 DC).

CONCLUSION

Low simple myopic astigmatism improved near visual performance in monofocal IOL implants at the expense of degradation of distance VA. ATR astigmatism provided better TPS than WTR astigmatism. This benefit of ATR over WTR astigmatism on reading performance on the Thai alphabet confirmed the role of axis orientation on near visual performance.

摘要

背景

低度单纯近视散光的屈光目标可增加单焦点人工晶状体(IOL)植入后的焦深和近视力表现。本研究使用泰国MNREAD视力表,调查散光及其轴位对远视力和近视力(VA)以及泰语字母的近视力表现的影响。

设计

研究性模拟。

方法

使用泰国MNREAD视力表单眼评估31只假晶状体眼(62.8±8.55岁)的远视力(6.0米)、近视力(40厘米)和近视力表现(最大阅读速度[MRS]、阈值印刷字体大小[TPS]和阅读视力[RA])。使用试验镜片模拟六种屈光状态:±0.00 DS[远距聚焦]、+1.00×90[逆规(ATR)]、+2.00×90[逆规]、+1.00×180[顺规(WTR)]、+2.00×180[顺规]和+3.00 DS[近距聚焦]。

结果

与+0.00 DS[远距聚焦]相比,球镜和散光性离焦会降低远视力(p<0.001)。相同度数的逆规和顺规散光之间,远视力无显著差异。与其他屈光状态相比,+3.00 DS时近视力更好(p值<0.001)。逆规散光的近视力表现(阈值印刷字体大小[TPS])明显优于顺规散光(+1.00 DC和+2.00 DC时p均<0.001)。

结论

低度单纯近视散光改善了单焦点IOL植入后的近视力表现,但以远视力下降为代价。逆规散光比顺规散光提供了更好的TPS。逆规散光在泰语字母阅读表现上优于顺规散光,这证实了轴位方向对近视力表现的作用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fb15/11663699/09e19333ba4b/OPTH-18-3815-g0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验