Suppr超能文献

宫内节育器移位致乙状结肠穿孔的诊断与外科治疗:1例病例报告

Perforation of sigmoid colon by a migrated intrauterine contraceptive device (IUCD), diagnosis and surgical management: a case report.

作者信息

Khan Muhammad E A, Kelly Elaine, Haidaran Ahmed I D

机构信息

Bantry General Hospital, Bantry, County Cork, P75 DX93, Republic of Ireland.

Cork University Hospital, Wilton, Cork, T12 DC4A, Republic of Ireland.

出版信息

J Surg Case Rep. 2024 Dec 26;2025(1):rjae803. doi: 10.1093/jscr/rjae803. eCollection 2025 Jan.

Abstract

We describe the case of a 43-year-old woman presented with an 8-month history of intermittent non-specific abdominal pain. She had an Intrauterine Contraceptive Device (IUCD) inserted 4-years ago and the device was still in-situ. After initial gynaecological assessment, further clinical radiological investigations, computerized tomography imaging showed that the intraluminal part of the radiological foreign body was seen to be possibly perforating the sigmoid colon after having migrated. Diagnostic laparoscopy confirmed this and a laparotomy was performed to remove the foreign body (IUCD) followed by primary closure of the defect in the sigmoid colon.

摘要

我们描述了一位43岁女性的病例,她有8个月间歇性非特异性腹痛的病史。她4年前放置了宫内节育器(IUCD),该节育器仍在原位。经过初步妇科评估及进一步临床影像学检查,计算机断层扫描成像显示,放射学异物的管腔内部分在迁移后似乎穿透了乙状结肠。诊断性腹腔镜检查证实了这一点,随后进行剖腹手术取出异物(IUCD),并对乙状结肠的缺损进行一期缝合。