Shetty Naren, Patel Yash, Ranade Reshma, Jain Akash, Narasimhan Raghav, Bansod Apurva, Nuijts Rudy
Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India.
University Eye Clinic Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands.
Indian J Ophthalmol. 2025 Mar 1;73(3):396-400. doi: 10.4103/IJO.IJO_348_24. Epub 2024 Dec 27.
To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).
Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.
The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.
We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.
使用术中光谱域光学相干断层扫描(SD - OCT),研究人工晶状体(IOL)触觉 - 光学交界处垂直与水平方向对IOL与后囊膜接触的影响。
50例患有老年性未成熟白内障的患者的50只眼睛,由一位经验丰富的外科医生进行表面麻醉下的超声乳化手术并植入单焦点IOL。使用Rescan 700 SD - OCT系统进行术中成像。这些患者在植入IOL后,先将触觉部分水平放置,然后垂直放置,使用术中SD - OCT进行成像。
与水平方向相比,当触觉部分垂直放置时,晶状体囊膜后表面与IOL后表面之间的垂直高度显著降低。在分析垂直和水平轴扫描时均发现了这种差异。
我们发现当IOL的触觉 - 光学交界处垂直放置时,后囊膜与IOL后表面之间的接触更大。这项研究还表明需要更新的 toric IOL设计,使触觉部分能够垂直放置,从而使IOL与囊袋之间有更好的接触。