• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

A gamma-ray imaging method for multiple radionuclides and low-activity radioactive sources.

作者信息

Fan Donghai, Wu Rui, Wei Dengke, Li Yingrui, Tan Tingting, Zha Gangqiang

机构信息

State Key Laboratory of SolidifiCation Processing, and MIIT Key Laboratory of Radiation Detection Materials and Devices, Northwestern Polytechnical University, Xi'an, 710072, China.

State Key Laboratory of SolidifiCation Processing, and MIIT Key Laboratory of Radiation Detection Materials and Devices, Northwestern Polytechnical University, Xi'an, 710072, China.

出版信息

J Environ Radioact. 2025 Feb;282:107606. doi: 10.1016/j.jenvrad.2024.107606. Epub 2024 Dec 26.

DOI:10.1016/j.jenvrad.2024.107606
PMID:39729878
Abstract

Gamma-ray coded-aperture imaging technology has important applications in the fields of nuclear security, isolated source detection, and the decommissioning of nuclear facilities. However, artifacts can reduce the quality of reconstructed images and affect the identification of the intensity and location of radioactive sources. In this paper, a gamma-ray coded-aperture imaging method based on primitive and reversed coded functions (PRCF) was proposed to reduce imaging artifacts. Building on this, the PRCF method was improved by integrating energy spectral information collected by the detector. By selecting energy intervals corresponding to characteristic energies of different radioactive sources for data filtering, the imaging capability of the PRCF method was further enhanced for multiple radioactive sources. Through simulation, the selection range of the correction factor in the PRCF method was determined. Single-source and multi-source imaging experiments were conducted using the self-built coded-aperture imaging system based on a CdZnTe pixel detector, and the selection criteria for the energy interval ranges of different radioactive sources were established. Compared with the conventional maximum likelihood expectation maximization (MLEM) method, the improved PRCF method not only effectively reduced artifacts and enhanced the imaging quality, but also ensured the accuracy of imaging results for multiple radioactive sources. Moreover, through imaging experiments using low-activity Cs and high-activity Am and Ba, it was demonstrated that the PRCF method can achieve low-count imaging in complex environments, providing a solution for imaging low-activity radioactive sources.

摘要

相似文献

1
A gamma-ray imaging method for multiple radionuclides and low-activity radioactive sources.
J Environ Radioact. 2025 Feb;282:107606. doi: 10.1016/j.jenvrad.2024.107606. Epub 2024 Dec 26.
2
Quantitative gamma-ray imaging with coded aperture method.采用编码孔径法的定量伽马射线成像。
Sci Rep. 2025 Apr 26;15(1):14587. doi: 10.1038/s41598-025-97206-w.
3
CdTe compact gamma camera for coded aperture imaging in radioguided surgery.放射性导向手术中编码孔径成像用碲化镉紧凑型伽马相机。
Phys Med. 2020 Jan;69:223-232. doi: 10.1016/j.ejmp.2019.12.024. Epub 2020 Jan 7.
4
Aperture collimation correction and maximum-likelihood image reconstruction for near-field coded aperture imaging of single photon emission computerized tomography.用于单光子发射计算机断层扫描近场编码孔径成像的孔径准直校正和最大似然图像重建。
IEEE Trans Med Imaging. 2006 Jun;25(6):701-11. doi: 10.1109/tmi.2006.873298.
5
Monte Carlo simulation of gamma-ray spectra from natural radionuclides recorded by a NaI detector in the marine environment.利用碘化钠探测器记录海洋环境中天然放射性核素γ射线能谱的蒙特卡罗模拟。
Appl Radiat Isot. 2006 Jan;64(1):116-23. doi: 10.1016/j.apradiso.2005.07.011. Epub 2005 Sep 8.
6
Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.使用带有针孔准直器的CZT单光子发射计算机断层显像(SPECT)系统对(99m)锝/(123)碘双放射性核素成像进行散射和串扰校正
Med Phys. 2015 Dec;42(12):6895-911. doi: 10.1118/1.4934830.
7
A hybrid coded-aperture and Compton camera based on cerium-doped GdAlGaO scintillators coupled with multi-pixel photon counter arrays.一种基于掺铈钆铝镓氧闪烁体与多像素光子计数器阵列耦合的混合编码孔径和康普顿相机。
Rev Sci Instrum. 2022 Nov 1;93(11):113103. doi: 10.1063/5.0097257.
8
SPECT Imaging of 2-D and 3-D Distributed Sources with Near-Field Coded Aperture Collimation: Computer Simulation and Real Data Validation.基于近场编码孔径准直的二维和三维分布式源的单光子发射计算机断层显像:计算机模拟与真实数据验证
J Med Biol Eng. 2016;36:32-43. doi: 10.1007/s40846-016-0111-6. Epub 2016 Feb 18.
9
Gamma-ray imaging with a time-modulated random coded aperture.基于时间调制随机编码孔径的伽马射线成像
Rev Sci Instrum. 2019 Jan;90(1):015107. doi: 10.1063/1.5050211.
10
Discrimination between natural and other gamma ray sources from environmental gamma ray dose rate monitoring data.从环境伽马射线剂量率监测数据中区分天然和其他伽马射线源。
Radiat Prot Dosimetry. 2015 Nov;167(1-3):293-7. doi: 10.1093/rpd/ncv265. Epub 2015 May 5.