Suppr超能文献

垂直根折与牙隐裂:离体去除纤维桩后通过显微CT评估根管治疗后牙根牙本质状况

Vertical root fractures and cracked teeth: post-endodontic root dentinal status through micro-CT assessment after ex vivo fiber post removal.

作者信息

Cavalcante Daniele Moreira, Tavares Sandro J O, Purger Luiz Otávio, Scelza Pantaleo, Gallito Marco Antonio, Saddock Aline, Lopes Ricardo Tadeu, Scelza Miriam F Zaccaro

机构信息

Departament of Clinic Dentistry, UFF- Universidade Federal Fluminense, Niterói, RJ, Brazil.

Post-Graduate Program in Dentistry, UFF- Universidade Federal Fluminense, Niterói, RJ, Brazil.

出版信息

Clin Oral Investig. 2024 Dec 28;29(1):32. doi: 10.1007/s00784-024-06116-0.

Abstract

OBJECTIVES

This study aimed to investigate cracked teeth and vertical root fracture observable on micro-CT images of extracted roots of mandibular incisors, after fiber post removal.

MATERIALS AND METHODS

Thirty mandibular incisors were selected with any degree of slight incisal wear inspected with the aid of a stereomicroscope under 12x magnification, in order to have a group of young adult specimens according to the criteria of Hugoson et al. A sample of twelve mandibular incisors were selected, aged between 20 and 30 years old, with similar dentine volume and thickness. The specimens were scanned in a micro-computed tomography (micro-CT) device and submitted to root canal shaping, root canal filling, post space preparation, post placement and post removal.

RESULTS

From a total of six experimental endodontic timepoints until post removal of 12 mandibular incisors, 64,800 cross-sectional images were analyzed and no vertical root fracture (VRF) or cracked tooth were detected.

CONCLUSIONS

Micro-CT assessment after ex vivo fiber post removal did not detect vertical root fracture or cracked tooth formation in the root canal walls of mandibular incisors.

CLINICAL RELEVANCE

This study highlighted that fiber post removal per se was not able to propagate VRF or cracked tooth formation or promoted any interruption of the integrity of human root dentin.

摘要

目的

本研究旨在调查下颌切牙拔除牙根在纤维桩取出后,微计算机断层扫描(micro-CT)图像上可观察到的牙隐裂和垂直根折情况。

材料与方法

根据Hugoson等人的标准,选取30颗有任何程度轻度切缘磨损的下颌切牙,在12倍放大率的体视显微镜下检查,以获得一组年轻成人标本。从其中选取12颗下颌切牙作为样本,年龄在20至30岁之间,牙本质体积和厚度相似。将标本在微计算机断层扫描(micro-CT)设备中进行扫描,并进行根管预备、根管充填、桩道预备、桩置入和桩取出操作。

结果

在12颗下颌切牙从根管预备到桩取出的总共6个实验性牙髓治疗时间点中,分析了64,800张横断面图像,未检测到垂直根折(VRF)或牙隐裂。

结论

离体纤维桩取出后进行的微计算机断层扫描评估未在下颌切牙根管壁中检测到垂直根折或牙隐裂形成。

临床意义

本研究强调,纤维桩取出本身不会导致垂直根折或牙隐裂的扩展,也不会破坏人牙根牙本质的完整性。