Utility of preoperative ultrasound in assessing the adequacy of autograft for anterior cruciate ligament reconstruction: a systematic review and meta-analysis.

作者信息

Fucaloro Stephen, Schreiner Gabriella, Ward Mark, Krivicich Laura, Bragg Jack, Harkey Matthew, Salzler Matthew

机构信息

Tufts University School of Medicine, Boston, MA, USA.

Department of Orthopaedic Surgery, Tufts Medical Center, Boston, MA, USA.

出版信息

Skeletal Radiol. 2025 Apr;54(4):869-878. doi: 10.1007/s00256-024-04860-8. Epub 2024 Dec 27.

Abstract

OBJECTIVE

Anterior cruciate ligament (ACL) reconstruction using tendon autograft requires imaging to evaluate graft adequacy. Ultrasound (US) offers an efficient adjunct to MRI; however, the utility of US is variable in prior literature and should be investigated. The primary aim of this study is to provide a statistical appraisal of literature assessing correlation of preoperative US measurements with intraoperative size of autografts during ACL reconstruction.

MATERIALS AND METHODS

PubMed, Embase, and Web of Science databases were queried for studies comparing preoperative US-based measurements to intraoperative measurements of autografts to assess graft adequacy (defined as > 8 mm diameter). Correlation coefficients from studies comparing combined cross-sectional area (CCSA) of autograft tendons on US to intraoperative autograft tendon diameters were collected and pooled. Random-effects models were generated to compare sensitivity, specificity, positive predictive values (PPV), and negative predictive value (NPV) for the identification of adequate graft sizes.

RESULTS

Eleven studies compared preoperative measurements of autograft size to intraoperative measurements. Meta-analysis of studies assessing hamstring tendon CCSA on US in comparison to intraoperative tendon diameters revealed a pooled correlation coefficient of 0.54 (CI 0.41-0.66, I = 9.6%). Three studies reported if US correctly identified adequate graft sizes, demonstrating sensitivity of 83% (I = 0.0%) and specificity of 78% (I = 49.2%). PPV was 91% (I = 0.0%), and NPV was 62% (I = 11.7%).

CONCLUSION

Hamstring CCSA on US has moderate correlation with intraoperative diameter, high sensitivity (83%), moderate specificity (78%), and very high PPV (91%) for identifying adequately sized autografts for ACL reconstruction.

摘要

目的

使用自体肌腱进行前交叉韧带(ACL)重建需要影像学检查来评估移植物的合适程度。超声(US)是磁共振成像(MRI)的一种有效辅助手段;然而,在既往文献中,超声的实用性存在差异,需要进行研究。本研究的主要目的是对评估ACL重建术中术前超声测量值与自体移植物术中尺寸相关性的文献进行统计学评价。

材料与方法

检索PubMed、Embase和Web of Science数据库,查找比较基于术前超声测量与自体移植物术中测量以评估移植物合适程度(定义为直径>8 mm)的研究。收集并汇总比较超声上自体移植物肌腱的联合横截面积(CCSA)与术中自体移植物肌腱直径的研究的相关系数。生成随机效应模型,以比较识别合适移植物尺寸的敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)。

结果

11项研究比较了自体移植物大小的术前测量值与术中测量值。对评估超声上腘绳肌腱CCSA与术中肌腱直径的研究进行荟萃分析,结果显示汇总相关系数为0.54(95%CI 0.41 - 0.66,I² = 9.6%)。三项研究报告了超声是否正确识别合适的移植物尺寸,敏感性为83%(I² = 0.0%),特异性为78%(I² = 49.2%)。PPV为91%(I² = 0.0%),NPV为62%(I² = 11.7%)。

结论

超声上腘绳肌腱的CCSA与术中直径具有中等相关性,对于识别ACL重建中尺寸合适的自体移植物具有高敏感性(83%)、中等特异性(78%)和非常高的PPV(91%)。