Chourasia Hemant Ramesh, Chohan Hitesh, Al-Maswary Arwa, Ghazwani Hadi Hassan, Harbi Hafiz Hadi, Khormi Nouh Hassan, Dewan Harisha, Bajawi Hashim, Tarrosh Mohammed Y
Department of Restorative Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
Department of Restorative and Aesthetic Dentistry, Faculty of Dentistry, Sana'a University, Sana'a, Yemen.
Med Sci Monit. 2025 Jan 2;31:e946794. doi: 10.12659/MSM.946794.
BACKGROUND This cone beam computed tomography (CBCT) endodontics study aimed to compare the canal-centering ability and canal transportation of Edgefile X7 and HyFlex EDM files in moderately curved mesiobuccal (MB) root canals of 30 mandibular first permanent molar teeth. MATERIAL AND METHODS Thirty permanent mandibular first molars with 10° and 24° of mesial root curvature were selected and scanned with CBCT. Two experimental groups of 15 each were made: group I: HyFlex EDM, and group II: Edgefile X7. The MB canals were instrumented, and CBCT scans were repeated. The distance from MB canal to the outer wall of the root was measured on pre- and post-instrumentation scans at 3 mm, 6 mm, and 9 mm from the apex. Canal transportation and centering ability were determined using established calculation methods. RESULTS For HyFlex EDM, average canal transportation was 0.01±0.17 mm, -0.10±0.21 mm, and 0.03±0.33 mm at 3 mm, 6 mm, and 9 mm, respectively; for Edgefile X7, average canal transportation was -0.02±0.21 mm, 0.07±0.22 mm, and -0.12±0.23 mm, respectively. HyFlex EDM group showed considerable canal transportation at 6 mm (P<0.05), while both groups showed non-significant differences at 3 mm and 9 mm. CONCLUSIONS At levels of 3 mm, 6 mm, and 9 mm, canal transportation was observed either on the mesial or distal surface of the canal curvature by HyFlex EDM and Edgefile X7 file systems. Compared with the HyFlex EDM file system, the Edgefile X7 file system showed reduced canal transportation and improved canal-centering ability.
背景 本锥形束计算机断层扫描(CBCT)牙髓病学研究旨在比较Edgefile X7和HyFlex EDM锉在30颗下颌第一恒磨牙中度弯曲的近中颊(MB)根管中的根管居中能力和根管偏移情况。材料与方法 选取30颗近中根弯曲度为10°和24°的下颌第一恒磨牙,用CBCT进行扫描。将其分为两个实验组,每组15颗:第一组:HyFlex EDM锉;第二组:Edgefile X7锉。对MB根管进行预备,并再次进行CBCT扫描。在根管预备前后的扫描图像上,测量根尖上方3mm、6mm和9mm处MB根管至牙根外壁的距离。采用既定的计算方法确定根管偏移和根管居中能力。结果 对于HyFlex EDM锉,在根尖上方3mm、6mm和9mm处的平均根管偏移分别为0.01±0.17mm、-0.10±0.21mm和0.03±0.33mm;对于Edgefile X7锉,平均根管偏移分别为-0.02±0.21mm、0.07±0.22mm和-0.12±0.23mm。HyFlex EDM锉组在6mm处显示出显著的根管偏移(P<0.05),而两组在3mm和9mm处均无显著差异。结论 在根尖上方3mm、6mm和9mm处,HyFlex EDM锉和Edgefile X7锉系统在根管弯曲的近中或远中表面均观察到根管偏移。与HyFlex EDM锉系统相比,Edgefile X7锉系统显示出减少的根管偏移和改善的根管居中能力。