Walber Gabriela Blauth, Poloni José Antonio Tesser, Rotta Liane Nanci
117303 Graduate Program in Health Sciences, Federal University of Health Sciences of Porto Alegre , Porto Alegre, Brazil.
Controllab, Rio de Janeiro, Brazil.
Clin Chem Lab Med. 2025 Jan 3;63(5):979-986. doi: 10.1515/cclm-2024-1199. Print 2025 Apr 28.
To evaluate urinalysis parameters useful for identifying mixed cultures in urine culture using an automated urinary particle analyzer to assess quality indicators (QIs) for urine sample contamination.
A retrospective observational cross-sectional study was conducted with 2,527 urine samples from patients of a quaternary hospital in Brazil. Urine samples were processed simultaneously in Sysmex UF-5000 flow cytometry analyzer (urinalysis) and MALDI-TOF (culture).
For all samples, a cutoff of 123.8 bacteria/µL was established to discriminate culture-negative specimens. ROC curve indicated the following cutoffs for females and males, respectively: 193.65 and 23.55 bacteria/µL, and 21.35 and 5.05 squamous epithelial cells (SEC)/µL, with the latter two related to scenarios of sample contamination/colonization through mixed cultures. Performing univariate logistic regression, we found a 2.78 (CI95 %: 2.12-3.65) times higher chance of probable mixed culture when SEC values were above the cutoffs for each sex, and 6.91(CI95 %: 4.56-10.47) times for bacteria. For multivariate logistic regression, the OR values were 1.62 (CI95 %: 1.21-2.15) and 5.82 (CI95 %: 3.77-8.98), respectively.
The fluorescent flow cytometry analyzers could efficiently identify urinary bacteria counts associated with contamination/colonization scenarios using the cutoffs of 21.35 SEC/µL for women and 5.05 SEC/µL for men. The cutoffs for bacteria/µL (193.65 for females and 23.55 for males) indicated that the presence of bacteria in male samples may be more associated with urinary tract infections (UTIs), while in female samples, it may be associated with either UTIs or contamination/colonization scenarios. This makes the analyzer a helpful tool as QI of sample contamination in urine cultures.
使用自动尿液颗粒分析仪评估尿液分析参数,以识别尿培养中的混合菌,并评估尿液样本污染的质量指标(QIs)。
对巴西一家四级医院患者的2527份尿液样本进行回顾性观察横断面研究。尿液样本在Sysmex UF - 5000流式细胞仪分析仪(尿液分析)和基质辅助激光解吸电离飞行时间质谱仪(培养)中同时进行处理。
对于所有样本,确定123.8个细菌/微升的临界值以区分培养阴性标本。ROC曲线分别显示女性和男性的以下临界值:193.65和23.55个细菌/微升,以及21.35和5.05个鳞状上皮细胞(SEC)/微升,后两者与通过混合菌导致的样本污染/定植情况相关。进行单因素逻辑回归分析时,我们发现当SEC值高于各性别临界值时,可能存在混合菌的几率高2.78倍(95%置信区间:2.12 - 3.65),细菌数量高于临界值时几率高6.91倍(95%置信区间:4.56 - 10.47)。对于多因素逻辑回归分析,OR值分别为1.62(95%置信区间:1.21 - 2.15)和5.82(95%置信区间:3.77 - 8.98)。
荧光流式细胞仪分析仪可以使用女性21.35个SEC/微升和男性5.05个SEC/微升的临界值有效地识别与污染/定植情况相关的尿液细菌计数。细菌/微升的临界值(女性为193.65,男性为23.55)表明男性样本中细菌的存在可能与尿路感染(UTIs)更相关,而在女性样本中,可能与UTIs或污染/定植情况相关。这使得该分析仪成为尿液培养中样本污染质量指标的有用工具。