• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

A Novel Technique With Buttress Plating for Comminuted Base Fractures of the Proximal Phalanx.

作者信息

Cha Soo Min, Nho Jae Hwi, Ga In Ho, Kim Yong Hwan

机构信息

From the Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon.

Department of Orthopaedic Surgery, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul.

出版信息

Ann Plast Surg. 2025 Feb 1;94(2):169-176. doi: 10.1097/SAP.0000000000004181. Epub 2024 Dec 10.

DOI:10.1097/SAP.0000000000004181
PMID:39745254
Abstract

BACKGROUND

Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

METHODS

Thirty-eight patients diagnosed with comminuted basal fracture of the PP were admitted between January 2014 and December 2020. Nineteen of these patients met the inclusion/exclusion criteria and were investigated in this retrospective study. Focusing only on preventing the volar tilt/collapse of the articular cartilage from the vertical position due to comminuted metaphysis, such as the "buttress concept by locking plate," the defect was filled with bone grafts. Meticulous repair of the incised central tendon effectively stabilized it by tightening the sagittal band and capsule of the metacarpophalangeal joint. It also acted as an envelope with proper sealing to minimize the loss of grafted bone materials.

RESULTS

Among the 19 patients, the mean patient age was 58.94 years, and the male/female ratio was 6:13. The mean follow-up period was 3.15 years, and the mean BMD was -0.15. Complete union was achieved after a mean of 9.63 weeks, without complications requiring secondary intervention. Two patients complained of skin lesion associated with PDS suture material, but this material spontaneously resolved by 4 weeks postoperatively. The mean extension lag at the proximal interphalangeal joint was 3.68 degrees, and the total active range of motion (TAM) was 256.38 degrees. Among the 19 patients, 6 were categorized as having a "good" modified Belsky classification, and the other patients all had an "excellent" classification. The mean articular-dorsal cortex angle was 85 ± 3.33 degrees at the final follow-up, which was slightly less than the normal value with statistical difference ( P < 0.05); however, it did not correlate with the TAM statistically ( r = 0.126, P = 0.608). Clinical outcomes were also satisfactorily evaluated using the VAS and DASH scores.

CONCLUSIONS

A low-profile locking plate is an effective option for extra-articular, severely comminuted basal fractures of the PP using the buttress concept in terms of clinical outcomes, such as finger movement and proper union.

摘要

相似文献

1
A Novel Technique With Buttress Plating for Comminuted Base Fractures of the Proximal Phalanx.
Ann Plast Surg. 2025 Feb 1;94(2):169-176. doi: 10.1097/SAP.0000000000004181. Epub 2024 Dec 10.
2
Dorsal versus lateral plate fixation of finger proximal phalangeal fractures: a retrospective study.手指近节指骨骨折的背侧与外侧钢板固定:一项回顾性研究
Arch Orthop Trauma Surg. 2017 Apr;137(4):567-572. doi: 10.1007/s00402-017-2650-x. Epub 2017 Feb 24.
3
Locking plate fixation in comminuted coronoid fractures with partial loss of the articular cartilage - Of basal-1 type according to the O'Driscoll classification.关节软骨部分缺失的粉碎性冠突骨折的锁定钢板固定术——根据奥德里斯科尔分类为基底-1型。
Injury. 2024 Jun;55(6):111550. doi: 10.1016/j.injury.2024.111550. Epub 2024 Apr 9.
4
Volar, Dorsal, and Lateral Locking Plate Fixation for Pilon Fractures.
Tech Hand Up Extrem Surg. 2017 Mar;21(1):22-27. doi: 10.1097/BTH.0000000000000148.
5
Dorsal transosseous reduction and locking plate fixation for articular depressed middle phalangeal base fracture.经背侧穿骨复位及锁定钢板固定治疗关节面塌陷的中节指骨基底部骨折
Arch Orthop Trauma Surg. 2019 Jan;139(1):141-145. doi: 10.1007/s00402-018-3074-y. Epub 2018 Nov 23.
6
Comparison of low-profile plate-screw and Kirschner-wire osteosynthesis outcomes in extra-articular unstable proximal phalangeal fractures.低轮廓钢板螺钉与克氏针内固定治疗关节外不稳定型近节指骨骨折的疗效比较
Eur J Orthop Surg Traumatol. 2019 Apr;29(3):597-604. doi: 10.1007/s00590-018-2342-4. Epub 2018 Nov 13.
7
Supplemental metaphyseal fixation of severe comminuted distal radius fracture with a mini plate.使用微型钢板对严重粉碎性桡骨远端骨折进行补充干骺端固定。
BMC Musculoskelet Disord. 2025 Feb 27;26(1):201. doi: 10.1186/s12891-025-08332-5.
8
Dorsal Plating for Intra-articular Middle Phalangeal Base Fractures With Volar Instability.用于治疗伴掌侧不稳定的关节内中节指骨基底骨折的背侧钢板固定术
Hand (N Y). 2019 Sep;14(5):620-625. doi: 10.1177/1558944718777868. Epub 2018 May 23.
9
Volar plating for intra-articular fracture of the base of the proximal phalanx.
J Hand Surg Am. 2007 Oct;32(8):1299-303. doi: 10.1016/j.jhsa.2007.07.020.
10
Plate fixation of extra-articular fractures of the proximal phalanx: do new implants cause less problems?近节指骨关节外骨折的钢板固定:新型植入物会减少问题吗?
Arch Orthop Trauma Surg. 2015 Mar;135(3):439-45. doi: 10.1007/s00402-015-2155-4. Epub 2015 Jan 11.

引用本文的文献

1
Symmetry-based analysis after surgical treatment of zygomaticomaxillary complex fractures using intraoperative cone-beam computed tomography: a retrospective case-control study.使用术中锥形束计算机断层扫描对颧上颌复合体骨折手术治疗后的对称性分析:一项回顾性病例对照研究。
Sci Rep. 2025 Feb 18;15(1):5898. doi: 10.1038/s41598-025-90481-7.