• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Hemorrheological effects of colloidal plasma substitutes infusion. A comparative study.

作者信息

Goto Y, Sakakura S, Hatta M, Sugiura Y, Kato T

出版信息

Acta Anaesthesiol Scand. 1985 Feb;29(2):217-23. doi: 10.1111/j.1399-6576.1985.tb02189.x.

DOI:10.1111/j.1399-6576.1985.tb02189.x
PMID:3976337
Abstract

Our objective was to investigate experimentally the easily overlooked effect of the clinical use of colloidal plasma substitutes on tissue perfusion. The experimental animals were dogs, and the study was carried out using several independent rheological experimental methods. The following are the principal findings: 1) Based on the observations made under a microscope, the stability of blood suspensions was best maintained by dextran-40 (Dex 40) and hydroxyethyl starch (HES0.55; Hespander), both of which cause little rouleaux formation by erythrocytes. In addition, the electronegativity of the erythrocyte membrane was simultaneously elevated. 2) The blood viscosity was greatly affected by the hematocrit and the serum protein concentration. 3) At a high shear rate, the blood viscosity among these colloidal plasma substitutes showed no great difference after infusion; in contrast, at a low shear rate, the blood viscosity after infusion of Dex 40 or HES0.55 was lower than after other substitutes. 4) The ratio of the viscosity at a low shear rate to the viscosity at a high shear rate is more significant and useful as a clinical indicator. On the basis of the preceding findings, Dex 40 and HES0.55 were generally superior to the other substitutes, especially HES0.55.

摘要

相似文献

1
Hemorrheological effects of colloidal plasma substitutes infusion. A comparative study.
Acta Anaesthesiol Scand. 1985 Feb;29(2):217-23. doi: 10.1111/j.1399-6576.1985.tb02189.x.
2
[In vivo effects of plasma substitutes on the rheologic properties of blood].[血浆代用品对血液流变学特性的体内效应]
J Mal Vasc. 1993;18(2):126-33.
3
Hematocrit, volume expander, temperature, and shear rate effects on blood viscosity.血细胞比容、扩容剂、温度及剪切速率对血液粘度的影响。
Anesth Analg. 2000 Sep;91(3):539-45. doi: 10.1097/00000539-200009000-00007.
4
[Rheological problems in the use of plasma substitutes].[血浆代用品使用中的流变学问题]
Bibl Haematol. 1971;37:309-12.
5
[In vitro modification of plasma viscosity and erythrocyte aggregation by four plasma substitutes].
Z Gesamte Inn Med. 1993 Dec;48(12):605-8.
6
[In vivo rheologic studies of plasma substitutes].
Ann Fr Anesth Reanim. 1992;11(5):516-25. doi: 10.1016/s0750-7658(05)80757-9.
7
[Effects of plasma substitutes on erythrocyte aggregation and blood viscosity].[血浆代用品对红细胞聚集和血液粘度的影响]
Masui. 1972 Jan;21(1):11-8.
8
The changes of low-shear-rate hemorheological properties depending on the fluid used for transfusion.低剪切率血液流变学特性随输血所用液体的变化。
Clin Hemorheol Microcirc. 2002;27(3-4):171-6.
9
Rheologic effects of plasma substitutes used for preoperative hemodilution.
Anesth Analg. 1994 Apr;78(4):740-5. doi: 10.1213/00000539-199404000-00021.
10
Rheological properties of commonly used plasma substitutes during preoperative normovolaemic acute haemodilution.
Br J Anaesth. 1996 Apr;76(4):519-25. doi: 10.1093/bja/76.4.519.

引用本文的文献

1
[Blood-saving procedures--anesthesiologic aspects. Autotransfusion procedures at a large clinic].
Unfallchirurgie. 1989 Aug;15(4):194-200.
2
Blood viscosity and circulatory shock.血液粘度与循环性休克
Intensive Care Med. 1989;15(2):72-8. doi: 10.1007/BF00295980.