Unlu Ozan, Gulcan Kersin Sinem, Cevlik Tulay, Unlu Nazmiye, Bilgen Hulya Selva, Ozek Eren, Sirikci Onder, Haklar Goncagul
Department of Biochemistry, School of Medicine, Marmara University, Istanbul, Turkey.
Biochemistry Laboratory, Marmara University Pendik Training and Research Hospital, Istanbul, Turkey.
Clin Pediatr (Phila). 2025 Jul;64(7):987-995. doi: 10.1177/00099228241309729. Epub 2025 Jan 8.
We aimed to investigate the diagnostic value of leukocyte cell population data (CPD) parameters obtained from an automated hematology analyzer to be able to use it in the diagnosis of neonatal sepsis. Our study was a retrospective and cross-sectional analysis. The neonates were classified into 3 groups: culture-positive sepsis (n = 20), clinical sepsis (n = 87), and control (n = 269). CPD parameters were determined during complete blood count (CBC) by volume-conductivity-scatter (VCS) technology with DxH 900 Coulter Cell Analyzer. Mean neutrophil volume (MNVNE), standard deviations of volumes of neutrophils (SDVNE), standard deviations of volumes of monocytes (SDVMO), and monocyte distribution width (MDW) were significantly increased in the culture-positive sepsis group compared with the clinical sepsis and control groups ( < .05). We have demonstrated the diagnostic utility of leukocyte CPD parameters, especially MNVNE, MDW, and their combination, for neonatal sepsis. These parameters are advantageous because they are obtained during routine CBC analysis without the need for additional blood collection and extra costs.
我们旨在研究通过自动血液分析仪获得的白细胞细胞群体数据(CPD)参数在新生儿败血症诊断中的价值,以便能够将其用于新生儿败血症的诊断。我们的研究是一项回顾性横断面分析。将新生儿分为3组:培养阳性败血症组(n = 20)、临床败血症组(n = 87)和对照组(n = 269)。通过DxH 900 Coulter细胞分析仪采用体积-电导率-散射(VCS)技术在全血细胞计数(CBC)过程中测定CPD参数。与临床败血症组和对照组相比,培养阳性败血症组的平均中性粒细胞体积(MNVNE)、中性粒细胞体积标准差(SDVNE)、单核细胞体积标准差(SDVMO)和单核细胞分布宽度(MDW)显著增加(P < .05)。我们已经证明白细胞CPD参数,尤其是MNVNE、MDW及其组合在新生儿败血症诊断中的实用性。这些参数具有优势,因为它们是在常规CBC分析过程中获得的,无需额外采血和额外费用。