Suppr超能文献

基于持续葡萄糖监测的数字表型分析在支持2型糖尿病个性化生活方式医学中的可行性。

Feasibility of digital phenotyping based on continuous glucose monitoring to support personalized lifestyle medicine in type 2 diabetes.

作者信息

van den Brink Willem J, van den Broek Tim J, Wopereis Suzan, Difrancesco Sonia, van der Horst Frans A L, de Hoogh Iris M

机构信息

Unit Healthy Living and Work, Netherlands Organization for Applied Scientific research (TNO), Sylviusweg 71, 2333 BE Leiden, the Netherlands.

Unit Healthy Living and Work, Netherlands Organization for Applied Scientific research (TNO), Sylviusweg 71, 2333 BE Leiden, the Netherlands.

出版信息

Maturitas. 2025 Mar;194:108188. doi: 10.1016/j.maturitas.2024.108188. Epub 2024 Dec 27.

Abstract

OBJECTIVES

Type 2 diabetes is a highly prevalent age-related chronic condition, with complex and heterogeneous pathogenesis. A 5-point oral glucose tolerance test can identify type 2 diabetes subtypes or "diabetypes" based on the degree of insulin resistance in muscle and/or liver, and beta-cell dysfunction. Due to its costly and invasive nature, the oral glucose tolerance test is not scalable. Presuming that differences in glucose and insulin dynamics manifest in continuous glucose monitoring profiles, we explore the potential of continuous glucose metrics to replace the oral glucose tolerance test for diabetyping.

STUDY DESIGN

In a prospective intervention study, 41 people with type 2 diabetes on lifestyle and/or metformin treatment wore a continuous glucose monitor during 3 control periods of 4 days. During each control period, participants underwent a 5-point oral glucose tolerance test after an overnight fast.

MAIN OUTCOME MEASURES

Continuous glucose monitoring data from the control periods, excluding the day of the oral glucose tolerance test, was retrospectively analyzed for associations with diabetypes, as well as Spearman correlations between bootstrapped continuous glucose features, including physiology-based and other time-series features, and oral glucose tolerance metrics.

RESULTS

Significant associations were observed between continuous glucose metrics (e.g., low and high blood glucose index, eA1c, and glucose excursions) and oral glucose tolerance metrics (e.g., 2-h glucose, disposition index, insulinogenic index). Furthermore, data-driven metrics (e.g., maximum shift, lumpiness) showed more selective correlations, indicating that data-driven metrics may contain additional information associated with oral glucose tolerance metrics.

CONCLUSIONS

These results indicate the potential of continuous glucose monitoring to replace the oral glucose tolerance test for diabetyping, driving proactive and personalized (lifestyle) treatment.

NETHERLANDS TRIAL REGISTER

NL7848.

摘要

目的

2型糖尿病是一种高度常见的与年龄相关的慢性疾病,其发病机制复杂且具有异质性。五点口服葡萄糖耐量试验可根据肌肉和/或肝脏中的胰岛素抵抗程度以及β细胞功能障碍来识别2型糖尿病亚型或“糖尿病类型”。由于其成本高昂且具有侵入性,口服葡萄糖耐量试验无法大规模开展。假定葡萄糖和胰岛素动态变化的差异在连续血糖监测数据中有所体现,我们探索利用连续血糖指标替代口服葡萄糖耐量试验进行糖尿病类型判定的潜力。

研究设计

在一项前瞻性干预研究中,41名接受生活方式干预和/或二甲双胍治疗的2型糖尿病患者在3个为期4天的对照期内佩戴连续血糖监测仪。在每个对照期,参与者在空腹过夜后接受五点口服葡萄糖耐量试验。

主要观察指标

回顾性分析对照期(不包括口服葡萄糖耐量试验当天)的连续血糖监测数据,以确定其与糖尿病类型的关联,以及自展连续血糖特征(包括基于生理学的特征和其他时间序列特征)与口服葡萄糖耐量指标之间的斯皮尔曼相关性。

结果

观察到连续血糖指标(如低血糖和高血糖指数、糖化血红蛋白估算值及血糖波动)与口服葡萄糖耐量指标(如2小时血糖、处置指数、胰岛素生成指数)之间存在显著关联。此外,数据驱动指标(如最大变化、不规则性)显示出更具选择性的相关性,这表明数据驱动指标可能包含与口服葡萄糖耐量指标相关的额外信息。

结论

这些结果表明连续血糖监测具有替代口服葡萄糖耐量试验进行糖尿病类型判定的潜力,从而推动积极主动且个性化的(生活方式)治疗。

荷兰试验注册编号

NL7848 。