Johnson Blaine, Onsager David, Tung Avery, Zarifa Rolla, Landeras Luis, Pinney Sean, Milner Ross, Jeevanandam Valluvan
Perfusion Services, UChicago Medicine, Chicago, Illinois.
Department of Surgery, University of Chicago, Chicago, Illinois.
Ann Thorac Surg Short Rep. 2023 Sep 19;2(1):121-124. doi: 10.1016/j.atssr.2023.08.004. eCollection 2024 Mar.
A 32-year-old woman with end-stage heart failure and complex anatomy underwent placement of a vascular graft to facilitate arterial cannulation during planned heart transplantation. The procedure involved anastomosis of a prosthetic graft to the abdominal aorta. The vascular graft was plugged with a silicone Foley catheter containing a stopper to maintain patency. This novel approach was safe when performed by a multidisciplinary surgical team experienced in vascular and adult congenital cardiac surgical procedures.