Suppr超能文献

使用来自同一胚胎培养的样本对非整倍体进行无创和微创植入前基因检测的比较。

Comparison of Non-Invasive and Minimally Invasive Preimplantation Genetic Testing for Aneuploidy Using Samples Derived from the Same Embryo Culture.

作者信息

Bednarska-Czerwińska Anna, Smoleń-Dzirba Joanna, Strychalska Anna, Sierka Wojciech, Wróblewska Urszula, Mermer Patrycja, Masarczyk Barbara, Jodłowiec-Lubańska Natalia, Kokot Anna, Simka-Lampa Klaudia, Zmarzły Nikola, Morawiec Emilia, Orczyk Aneta, Grabarek Beniamin Oskar

机构信息

Laboratory of Molecular Biology and Virology, Gyncentrum, 40-851 Katowice, Poland.

Collegium Medicum, WSB University, 41-300 Dąbrowa Górnicza, Poland.

出版信息

J Clin Med. 2024 Dec 25;14(1):33. doi: 10.3390/jcm14010033.

Abstract

: To assess the ploidy status of embryos via preimplantation genetic testing for aneuploidy (PGT-A), a biopsy of trophectoderm (TE) cells can be performed. However, this approach is considered invasive, and therefore the aim of this study was to identify the optimal sample type and sampling day for non-invasive or minimally invasive PGT-A (ni/miPGT-A) in terms of data quality and concordance rates with TE biopsies derived from the same embryos. : This study was performed using 239 embryo cultures. After optimization using 96 embryos, non-invasive spent culture media (SCM) and a minimally invasive combination of blastocoel fluid and SCM (BF+SCM), along with the corresponding TE samples, were collected from 143 embryos cultured for 5 days (n = 70) or 6 days (n = 73), and all were subjected to ni/miPGT-A with whole-genome amplification followed by next-generation sequencing. : The amplification failure rate was lower for SCM samples than for BF+SCM (SCM: 0.7%, 1/143 vs. BF+SCM: 7.7%, 11/143; = 0.005). The rate of ploidy concordance with TE was significantly higher for SCM samples than for BF+SCM samples (SCM: 83.7%, 118/141 vs. BF+SCM: 58%, 76/131; < 0.001). Among SCM samples, concordance rates were higher for samples derived from embryos cultured for 6 days (87.5%, 63/72) than for 5 days (79.7%, 55/69). In the embryos cultured for 6 days, discordant cases included five (6.9%) SCM samples with falsely negative (euploid) results that were deemed to be mosaic according to TE and four (5.6%) samples falsely found to be aneuploid. : SCM samples derived from embryos cultured for 6 days can be applied in niPGT-A with subsequent verification of aneuploid samples using TE biopsy.

摘要

为了通过胚胎植入前非整倍体基因检测(PGT-A)评估胚胎的倍性状态,可以对滋养外胚层(TE)细胞进行活检。然而,这种方法被认为具有侵入性,因此本研究的目的是从数据质量以及与来自同一胚胎的TE活检的一致性率方面,确定用于非侵入性或微创PGT-A(ni/miPGT-A)的最佳样本类型和采样日。本研究使用了239个胚胎培养物。在使用96个胚胎进行优化后,从143个培养5天(n = 70)或6天(n = 73)的胚胎中收集了非侵入性的废弃培养基(SCM)以及囊胚液和SCM的微创组合(BF+SCM),以及相应的TE样本,所有样本均进行了全基因组扩增后的ni/miPGT-A,随后进行下一代测序。SCM样本的扩增失败率低于BF+SCM样本(SCM:0.7%,1/143;BF+SCM:7.7%,11/143;P = 0.005)。SCM样本与TE的倍性一致性率显著高于BF+SCM样本(SCM:83.7%,118/141;BF+SCM:58%,76/131;P < 0.001)。在SCM样本中,来自培养6天胚胎的样本的一致性率高于培养5天的样本(87.5%,63/72;79.7%,55/69)。在培养6天的胚胎中,不一致的情况包括五个(6.9%)SCM样本,其结果为假阴性(整倍体),根据TE判断为嵌合体,以及四个(5.6%)样本被错误地发现为非整倍体。来自培养6天胚胎的SCM样本可应用于niPGT-A,随后使用TE活检对非整倍体样本进行验证。