Applicability of TB-LAMP test for diagnosis of pulmonary TB among HIV-positive individuals.

作者信息

Muriithi B, Bundi M M, Moriyasu T, Ahmed A, Mwamzuka M, Karama M, Kaneko S

机构信息

Nairobi Research Station, Nagasaki University Institute of Tropical Medicine (NUITM)-Kenya Medical Research Institute (KEMRI) Project, Nairobi, Kenya.

Kenya Medical Research Institute, KEMRI Graduate School, Nairobi, Kenya.

出版信息

IJTLD Open. 2025 Jan 1;2(1):26-32. doi: 10.5588/ijtldopen.24.0410. eCollection 2025 Jan.


DOI:10.5588/ijtldopen.24.0410
PMID:39802227
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC11724533/
Abstract

BACKGROUND: The loop-mediated isothermal amplification for TB (TB-LAMP) assay is more cost-effective and accessible than the Xpert MTB/RIF assay. This study aimed to evaluate the diagnostic performance of the TB-LAMP assay in individuals with and without HIV infection. METHODS: Patients aged ≥15 years presenting with symptoms of TB were included in the study. The TB-LAMP assay was performed alongside routine TB diagnostic methods, including the Xpert assay and smear microscopy, to evaluate discrepancies in test results and associated factors. RESULTS: A total of 903 patients were enrolled in the study. The positive percentage agreement for smear microscopy and TB-LAMP compared with the Xpert assay was respectively 54.3% (95% CI 46.6-61.8) and 76.6% (95% CI 69.9-82.6). Among HIV-positive individuals, the positive percentage agreement was 42.5% (95% CI 32.9-52.4) for smear microscopy and 68.9% (95% CI 59.1-77.5) for TB-LAMP. Factors such as age >60 years (adjusted OR 3.29, 95% CI 0.32-33.83), loss of appetite (aOR 0.30, 95% CI 0.13-0.70), and HIV-positive status (aOR 3.29, 95% CI 1.12-9.63) were associated with discrepancies between TB-LAMP and Xpert results. CONCLUSIONS: TB-LAMP demonstrated better agreement with the Xpert assay compared with smear microscopy in detecting TB among HIV-positive patients, suggesting that TB-LAMP could effectively replace smear microscopy.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/205f/11724533/02d1497156e1/ijtldopen24-0410f1.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/205f/11724533/02d1497156e1/ijtldopen24-0410f1.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/205f/11724533/02d1497156e1/ijtldopen24-0410f1.jpg

相似文献

[1]
Applicability of TB-LAMP test for diagnosis of pulmonary TB among HIV-positive individuals.

IJTLD Open. 2025-1-1

[2]
Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults.

Cochrane Database Syst Rev. 2014-1-21

[3]
The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi.

PLoS One. 2016-5-12

[4]
The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture.

Rev Inst Med Trop Sao Paulo. 2020-6-5

[5]
Chest X-ray interpretation does not complement Xpert MTB/RIF in diagnosis of smear-negative pulmonary tuberculosis among TB-HIV co-infected adults in a resource-limited setting.

BMC Infect Dis. 2021-1-13

[6]
Cost-Utility Analysis of Molecular Testing for Tuberculosis Diagnosis in Suspected Pulmonary Tuberculosis in Thailand.

Clinicoecon Outcomes Res. 2022-2-2

[7]
Evaluation of in-house loop-mediated isothermal amplification for tuberculosis diagnosis compared with Xpert MTB/RIF.

J Infect Dev Ctries. 2017-6-27

[8]
Accuracy of the tuberculosis molecular bacterial load assay to diagnose and monitor response to anti-tuberculosis therapy: a longitudinal comparative study with standard-of-care smear microscopy, Xpert MTB/RIF Ultra, and culture in Uganda.

Lancet Microbe. 2024-4

[9]
Diagnostic accuracy of TB-LAMP assay in patients with pulmonary tuberculosis...a case-control study in northern India.

Pulmonology. 2022

[10]
Diagnostic accuracy of TB-LAMP for pulmonary tuberculosis: a systematic review and meta-analysis.

BMC Infect Dis. 2019-3-19

本文引用的文献

[1]
Evolution of Laboratory Diagnosis of Tuberculosis.

Clin Pract. 2024-2-23

[2]
Evaluation of kit-based loop-mediated isothermal amplification (TB-LAMP) assay in the diagnosis of tubercular lymphadenitis.

Access Microbiol. 2023-11-9

[3]
Advances in tuberculosis control during the past decade.

Lancet Respir Med. 2023-4

[4]
New developments in tuberculosis diagnosis and treatment.

Breathe (Sheff). 2022-3

[5]
TB testing in HIV-positive patients prior to antiretroviral treatment.

Int J Tuberc Lung Dis. 2022-3-1

[6]
Effectiveness of GeneXpert® in the diagnosis of tuberculosis in people living with HIV/AIDS.

Rev Saude Publica. 2021

[7]
Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children.

J Pediatric Infect Dis Soc. 2022-1-27

[8]
Revisiting the methods for detecting : what has the new millennium brought thus far?

Access Microbiol. 2021-8-2

[9]
Xpert MTB/RIF and Xpert Ultra assays for screening for pulmonary tuberculosis and rifampicin resistance in adults, irrespective of signs or symptoms.

Cochrane Database Syst Rev. 2021-3-23

[10]
Diagnostic accuracy of TB-LAMP assay in patients with pulmonary tuberculosis...a case-control study in northern India.

Pulmonology. 2022

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索