Suppr超能文献

自制皮肤拉伸装置治疗足跟软组织缺损的临床疗效观察:一项回顾性单臂队列研究

Observation of the Clinical Efficacy of Self-Modified Skin-Stretching Device in the Treatment of Soft-Tissue Defects of the Heel: A Retrospective Single-Arm Cohort Study.

作者信息

Liu Shibo, Wang Yong, Peng Aqin, Zhang Yanlong

机构信息

Department of Hand and Foot Surgery, Affiliated Hospital of Chengde Medical University, Chengde, Hebei, China.

Department of Orthopedics Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China.

出版信息

Orthop Surg. 2025 Mar;17(3):858-868. doi: 10.1111/os.14340. Epub 2025 Jan 13.

Abstract

OBJECTIVE

Due to the poor skin mobility of the heel, there are few reports on the efficacy and safety of skin-stretching devices in the treatment of soft-tissue defects of the heel. Redesigning the claws of the stretching devices may be one of the solutions to the problem. This study was designed to investigate the clinical effect of self-modified skin-stretching device in the treatment of soft-tissue defects in the heel.

METHODS

From December 2017 to March 2022, 23 patients with heel soft-tissue defects were enrolled. There were 15 males and 8 females, with a mean age of 50 years (range, 28-73 years). Defect size, time of wound closure, duration of stretching time, and complications were documented. The American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score was used to evaluate functional outcomes, and pain was assessed by the visual analog scale (VAS) at the last follow-up. Statistical analysis was performed using t-tests and Mann-Whitney U test.

RESULTS

The mean follow-up time was 14.2 months. Primary wound closure was performed in 6 patients and delayed wound closure in 17 patients. The average time of wound closure was 14.3 days, and the average duration of stretching time was 23.5 days. Complications were observed in 9 patients. Finally, all wounds were healed. At the last follow-up, the average AOFAS score was 86.7, with 9 excellent, 13 good, and 1 fair results. The mean VAS score was 2.6.

CONCLUSIONS

Self-modified skin-stretching device is another option for treating heel soft-tissue defects. The technique can achieve good appearance and function with a low price and easy to install.

摘要

目的

由于足跟部皮肤移动性较差,关于皮肤拉伸装置治疗足跟部软组织缺损的疗效和安全性的报道较少。重新设计拉伸装置的爪部可能是解决该问题的方法之一。本研究旨在探讨自行改良的皮肤拉伸装置治疗足跟部软组织缺损的临床效果。

方法

2017年12月至2022年3月,纳入23例足跟部软组织缺损患者。其中男性15例,女性8例,平均年龄50岁(范围28 - 73岁)。记录缺损大小、伤口闭合时间、拉伸时间及并发症情况。采用美国矫形足踝协会(AOFAS)踝 - 后足评分评估功能结局,并在末次随访时采用视觉模拟评分法(VAS)评估疼痛程度。采用t检验和曼 - 惠特尼U检验进行统计学分析。

结果

平均随访时间为14.2个月。6例患者进行了一期伤口闭合,17例患者进行了延迟伤口闭合。伤口平均闭合时间为14.3天,平均拉伸时间为23.5天。9例患者出现并发症。最终,所有伤口均愈合。末次随访时,平均AOFAS评分为86.7分,其中优9例,良13例,可1例。平均VAS评分为2.6分。

结论

自行改良的皮肤拉伸装置是治疗足跟部软组织缺损的另一种选择。该技术能以较低的价格实现良好的外观和功能,且易于安装。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/87d2/11872368/d656fc9f7b37/OS-17-858-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验