Schilcher R B, Young J D, Baker L H
J Chromatogr. 1985 Jan 11;337(1):55-62. doi: 10.1016/0378-4347(85)80007-4.
An isocratic, sensitive, high-performance liquid chromatographic assay was developed for the determination of the tricyclic nucleoside 1,4,5,6,8-pentaazaacenaphthylene -3-amino-1,5-dihydro-5-methyl-1-beta-D-ribofuranosyl 5'-monophosphate (TCN-P; NSC 280594) and its dephosphorylated metabolite TCN (NSC 154020). Separation was obtained using a C18 Sep-Pak precolumn, a reversed-phase column, and a mobile phase of phosphate buffer--methanol (87.5:12.5, v/v) containing 0.0025 M tetrabutylammonium hydroxide. The absorbance of both TCN and TCN-P was monitored at 280 nm with a sensitivity limit of 10 ng/ml. The recovery was 54 +/- 6% and 51 +/- 8% (mean +/- S.D.) from plasma for TCN and TCN-P, respectively. Rapid enzymatic dephosphorylation of TCN-P in plasma and tissue samples was prevented by adding a large excess of adenosine 5'-monophosphate. The assay was used to determine plasma and tissue concentrations of TCN-P and TCN after administration of TCN-P to cancer patients in a Phase I clinical study.
建立了一种等度、灵敏的高效液相色谱法,用于测定三环核苷1,4,5,6,8-五氮杂苊烯-3-氨基-1,5-二氢-5-甲基-1-β-D-呋喃核糖基5'-单磷酸酯(TCN-P;NSC 280594)及其去磷酸化代谢产物TCN(NSC 154020)。使用C18 Sep-Pak预柱、反相柱以及含0.0025 M氢氧化四丁铵的磷酸盐缓冲液-甲醇(87.5:12.5,v/v)流动相进行分离。在280 nm处监测TCN和TCN-P的吸光度,灵敏度极限为10 ng/ml。TCN和TCN-P从血浆中的回收率分别为54±6%和51±8%(平均值±标准差)。通过加入大量过量的5'-单磷酸腺苷,可防止血浆和组织样品中TCN-P的快速酶促去磷酸化。在一项I期临床研究中,该测定法用于测定癌症患者服用TCN-P后血浆和组织中TCN-P和TCN的浓度。