Suppr超能文献

不同排尿样本储存时间、温度及防腐剂对基于多重磁珠的Oncuria膀胱癌免疫分析的影响

Effects of Different Voided Urine Sample Storage Time, Temperature, and Preservatives on Analysis with Multiplex Bead-Based Oncuria Bladder Cancer Immunoassay.

作者信息

Tanaka Sunao, Murakami Kaoru, Sakatani Toru, Lee Riko, Hogrefe Wayne, Siguencia Fernando, Rosser Charles J, Furuya Hideki

机构信息

Samuel Oschin Comprehensive Cancer Center, Cedars-Sinai Medical Center, Los Angeles, CA 90048, USA.

Nonagen Bioscience Corp., Los Angeles, CA 90010, USA.

出版信息

Diagnostics (Basel). 2025 Jan 9;15(2):138. doi: 10.3390/diagnostics15020138.

Abstract

Urinalysis accuracy requires reliable sample stability that is dependent on the chosen collection and storage conditions. The multiplex Oncuria bladder cancer immunoassay currently needs urine samples stored at 4 °C until analysis, which requires more effort, equipment, and workflow than storing samples at room temperature. Thus, successful sample storage at room temperature (20 °C) may reduce laboratory handling time and expenses. This study evaluated whether different voided urine sample collection and storage parameters affected subsequent biomarker analysis with Oncuria. The Oncuria simultaneously quantifies 10 protein analytes in urine to generate a bladder cancer diagnostic signature. : Samples were stored at varied temperatures (20 °C, 4 °C, -20 °C) for up to 1 month. The effects of adding two commercial urine sample stabilizers and antibiotics (trimethoprim) were also assessed. Subsequently, multiple potential biospecimen stabilizers were tested in urine samples and evaluated with Oncuria in hopes of allowing the urine sample to remain at room temperature for extended periods of time. : First, it was demonstrated that voided urine samples stored at room temperate without such stabilizers had different levels of the 10 analytes associated with the Oncuria test compared to voided urine samples stored at 4 °C. Next, we evaluated the effects of commercially available biospecimen stabilizers. Despite the addition of these stabilizers, the levels of the 10 analytes were altered when the samples were stored at room temperature for prolonged periods of time. Therefore, we could not identify a suitable biospecimen stabilizer that would not require sample refrigeration. : To minimize sample degradation/alteration after collection, voided urine samples should be refrigerated until analyzed with Oncuria as the refrigeration is advantageous for the storage and the transport of these urine samples.

摘要

尿液分析的准确性需要可靠的样本稳定性,这取决于所选的采集和储存条件。目前,Oncuria膀胱癌症多重免疫分析需要将尿液样本储存在4°C直至分析,这比在室温下储存样本需要更多的精力、设备和工作流程。因此,在室温(20°C)下成功储存样本可能会减少实验室处理时间和费用。本研究评估了不同的随机尿液样本采集和储存参数是否会影响随后使用Oncuria进行的生物标志物分析。Oncuria可同时对尿液中的10种蛋白质分析物进行定量,以生成膀胱癌诊断特征。样本在不同温度(20°C、4°C、-20°C)下储存长达1个月。还评估了添加两种商用尿液样本稳定剂和抗生素(甲氧苄啶)的效果。随后,在尿液样本中测试了多种潜在的生物样本稳定剂,并用Oncuria进行评估,希望能让尿液样本在室温下长时间保存。首先,结果表明,与储存在4°C的随机尿液样本相比,在室温下储存且未添加此类稳定剂的随机尿液样本中,与Oncuria检测相关的10种分析物水平不同。接下来,我们评估了市售生物样本稳定剂的效果。尽管添加了这些稳定剂,但当样本在室温下长时间储存时,10种分析物的水平仍会发生变化。因此,我们未能找到一种无需样本冷藏的合适生物样本稳定剂。为了尽量减少采集后样本的降解/改变,随机尿液样本在使用Oncuria分析之前应冷藏,因为冷藏有利于这些尿液样本的储存和运输。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f3ba/11763964/1266b5738adc/diagnostics-15-00138-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验