Suppr超能文献

轻度至中度多发性硬化症患者中躯干功能障碍量表挪威修订版的测量属性

Measurement properties of the Trunk Impairment Scale-modified Norwegian version among people with mild to moderate multiple sclerosis.

作者信息

Dahl Stine Susanne Haakonsen, Braaten Tonje, Arntzen Ellen Christin, Verheyden Geert, Fikke Hanne Kristin, Normann Britt

机构信息

Faculty of Nursing and Health Sciences, Nord University, Bodø, Norway.

Department of Community Medicine, University of Tromsø, Tromsø, Norway.

出版信息

Disabil Rehabil. 2025 Aug;47(17):4548-4556. doi: 10.1080/09638288.2025.2454299. Epub 2025 Jan 24.

Abstract

PURPOSE

The Trunk Impairment Scale-modified Norwegian version (TIS-modNV) measures trunk control for clinical and research purposes. This study examined the validity and reliability of the TIS-modNV in people with multiple sclerosis (pwMS).

MATERIALS AND METHODS

Sixty-eight pwMS (mild to moderate) participated. The TIS-modNV and the Mini-Balance Evaluation Systems Test (Mini-BESTest) scores were compared for using Spearman's rho (). TIS-modNV performance was videotaped and rated by four physiotherapists on two occasions. The and was analyzed via intraclass correlation coefficients (ICC), standard errors of measurement (SEM), Bland-Altman plots, and kappa statistics ().

RESULTS

Validity was demonstrated ( = 0.55-0.61). Interrater reliability for the total score was moderate to good (ICC(A,1) =0.67; ICC(C,1) = 0.78), and the SEM was 2 points (12.8%). Interrater reliability varied across the rater pairs (ICC(A,1) = 0.54-0.81) as displayed in the Bland-Altman plots. Item-level interrater agreement varied from poor to good ( = 0.10-0.79). Intrarater reliability of the total scores was moderate to good (ICC(A,1) = 0.67-0.82).

CONCLUSION

This study supports the construct validity and overall reliability of the TIS-modNV in pwMS with mild to moderate disability. However, variations in rater reliability need to be addressed.

摘要

目的

躯干功能障碍量表修订挪威版(TIS-modNV)用于临床和研究目的的躯干控制测量。本研究检验了TIS-modNV在多发性硬化症患者(pwMS)中的有效性和可靠性。

材料与方法

68名轻度至中度pwMS患者参与。使用Spearman等级相关系数(ρ)比较TIS-modNV和迷你平衡评估系统测试(Mini-BESTest)得分。对TIS-modNV表现进行录像,并由四名物理治疗师分两次进行评分。通过组内相关系数(ICC)、测量标准误差(SEM)、Bland-Altman图和kappa统计量(κ)分析ICC(A,1)和ICC(C,1)。

结果

证明了有效性(ρ = 0.55 - 0.61)。总分的评分者间信度为中等至良好(ICC(A,1) = 0.67;ICC(C,1) = 0.78),SEM为2分(12.8%)。如Bland-Altman图所示,评分者对之间的评分者间信度各不相同(ICC(A,1) = 0.54 - 0.81)。项目水平的评分者间一致性从差到好不等(κ = 0.10 - 0.79)。总分的评分者内信度为中等至良好(ICC(A,1) = 0.67 - 0.82)。

结论

本研究支持TIS-modNV在轻度至中度残疾pwMS中的结构效度和总体可靠性。然而,评分者信度的差异需要得到解决。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验