Suppr超能文献

一种用于评估平衡和姿势控制的新型设备——Quadrotics Poise Q10的有效性和可靠性。

Validity and reliability of a novel device to evaluate balance and postural control - Quadrotics Poise Q10.

作者信息

Yağcı Gözde, Metin Gülnihal, Yerli Sibel, Yalçın Ali İmran, Aksoy Songül, Topuz Semra, Erbahçeci Fatih

机构信息

Hacettepe University, Faculty of Physical Therapy and Rehabilitation, Department of Physiotherapy and Rehabilitation, Ankara, Türkiye.

Hacettepe University, Faculty of Physical Therapy and Rehabilitation, Department of Physiotherapy and Rehabilitation, Ankara, Türkiye; Pamukkale University, Faculty of Physiotherapy and Rehabilitation, Department of Physiotherapy and Rehabilitation, Denizli, Türkiye.

出版信息

J Biomech. 2025 Sep;190:112871. doi: 10.1016/j.jbiomech.2025.112871. Epub 2025 Jul 16.

Abstract

Assessment of balance using force platform-based methods are crucial for diagnosis and treatment in the fields of physiotherapy. This study evaluated the validity and reliability of the Quadrotics Poise Q10 in measuring postural sway and limits of stability, using simultaneous assessments with the Bertec force platform in 40 healthy participants. Postural sway was evaluated under four conditions. Limits of stability were analysed in the four directions. Pearson's correlation analysis was used to assess the concurrent and absolute validity of the Quadrotics Poise Q10. Intra and Inter-Rater reliability were examined using intraclass correlation coefficients (ICC), standard error of measurement, and Minimum Detectable Change. Additionally Limits of Agreement and Bland-Altman plots were conducted. A strong relationship was observed in anteroposterior and mediolateral sway on both hard and soft surfaces, with eyes open and closed (p < 0.05). Moderate to strong correlations were found for all directions excursions during the limits of stability test (p < 0.05). Intra-rater reliability analysis demonstrated high reliability for postural sway (ICC:0.60-0.87) and excellent reliability for LoS (ICC:0.91-0.95). Inter-rater reliability was found to be high across all test conditions, with ICC values ranging from 0.67 to 0.83 for postural sway and excellent reliability for LoS in the right and left directions (ICC = 0.93 and 0.91, respectively) and high in the forward and backward direcions (ICC = 0.67-0.71). The study's findings indicate that the newly developed device is valid and reliable for evaluating limits of stability and postural sway. However, Bland-Altman analysis variations highlighted in lower agreement under more challenging test conditions.

摘要

使用基于测力平台的方法评估平衡能力对于物理治疗领域的诊断和治疗至关重要。本研究通过与Bertec测力平台同时对40名健康参与者进行评估,来评价Quadrotics Poise Q10在测量姿势摆动和稳定性极限方面的有效性和可靠性。在四种条件下评估姿势摆动。在四个方向上分析稳定性极限。使用Pearson相关分析来评估Quadrotics Poise Q10的同时效度和绝对效度。使用组内相关系数(ICC)、测量标准误差和最小可检测变化来检验评分者内和评分者间的可靠性。此外,还进行了一致性界限分析和Bland-Altman图分析。在硬表面和软表面上,睁眼和闭眼时的前后向和内外侧摆动均观察到很强的相关性(p < 0.05)。在稳定性极限测试期间,所有方向偏移均发现中度至强相关性(p < 0.05)。评分者内可靠性分析表明,姿势摆动具有高可靠性(ICC:0.60 - 0.87),稳定性极限具有出色的可靠性(ICC:0.91 - 0.95)。发现在所有测试条件下评分者间可靠性都很高,姿势摆动的ICC值范围为0.67至0.83,稳定性极限在左右方向具有出色的可靠性(ICC分别为0.93和0.91),在前后方向具有高可靠性(ICC = 0.67 - 0.71)。该研究结果表明,新开发的设备在评估稳定性极限和姿势摆动方面是有效且可靠的。然而,Bland-Altman分析的差异突出显示在更具挑战性的测试条件下一致性较低。