Suppr超能文献

用于测量和处理心肺变量的微型计算机辅助监测系统:临床试验的初步结果。

Microcomputer-assisted monitoring system for measuring and processing cardiorespiratory variables: preliminary results of clinical trials.

作者信息

Hankeln K B, Michelsen H, Schipulle M, Engel H J, Beez M, Szreter T, Boehmert F

出版信息

Crit Care Med. 1985 May;13(5):426-31. doi: 10.1097/00003246-198505000-00013.

Abstract

A microcomputer-assisted monitoring system was developed for the continuous measuring and processing of cardiorespiratory variables, including: systemic and pulmonary arterial pressures, CVP, minute ventilation, inspired and expired O2 and CO2 concentrations, temperature, and heart rate. The primary data were converted to digital form, processed, displayed on a CRT monitor, and also stored for later evaluation. This system automatically calculated and displayed on-line and in real-time both primary measurements and derived cardiorespiratory variables, including: oxygen consumption, CO2 production, left and right ventricular stroke work, pulmonary venous admixture, and systemic and pulmonary vascular resistances. Printouts of the variables and trend graphs could be obtained for any desired time period. During its development, we tested this monitoring system in 30 critically ill patients, finding that the real-time calculation of cardiorespiratory variables was a great advantage during monitoring and treatment.

摘要

开发了一种微机辅助监测系统,用于连续测量和处理心肺变量,包括:体循环和肺动脉压、中心静脉压、分钟通气量、吸入和呼出的氧气及二氧化碳浓度、体温和心率。原始数据被转换为数字形式,进行处理,显示在阴极射线管显示器上,并存储以供后续评估。该系统自动在线实时计算并显示原始测量值和派生的心肺变量,包括:氧耗量、二氧化碳产生量、左右心室搏功、肺静脉混合血、体循环和肺血管阻力。可以获取任何所需时间段内变量的打印输出和趋势图。在开发过程中,我们在30例危重病患者中测试了该监测系统,发现心肺变量的实时计算在监测和治疗过程中具有很大优势。

相似文献

4
A microcomputer system for monitoring ventilation in neonates.
Int J Clin Monit Comput. 1986;3(1):11-6. doi: 10.1007/BF02916393.
5
Microcomputer-based haemodynamic monitoring during continuous extradural analgesia.
Br J Anaesth. 1986 Apr;58(4):457-60. doi: 10.1093/bja/58.4.457.
8
A microcomputer system for on-line monitoring of pulmonary function during artificial ventilation.
Int J Clin Monit Comput. 1989 Apr;6(2):99-107. doi: 10.1007/BF01720420.
10
A cotside microcomputer monitoring system for use in the neonatal intensive care unit.
Clin Phys Physiol Meas. 1983 Nov;4(4):373-80. doi: 10.1088/0143-0815/4/4/002.

引用本文的文献

1
Blood gas optodes are accurate but fragile.
J Anesth. 1994 Sep;8(3):379-81. doi: 10.1007/BF02514674.