Mockevičius Aurimas, Griškova-Bulanova Inga
Institute of Bioscience, Life Sciences Center, 54694 Vilnius University , Saulėtekio ave. 7, LT-10257, Vilnius, Lithuania.
Faculty of Medicine, Translational Health Research Institute, 54694 Vilnius University , Žaliųjų ež. str. 2, LT- 08406, Vilnius, Lithuania.
Rev Neurosci. 2025 Feb 5;36(6):577-586. doi: 10.1515/revneuro-2024-0165. Print 2025 Aug 26.
Auditory steady-state response (ASSR) is a robust method to probe gamma (>30 Hz) activity in a controlled manner. While typically the magnitude and the phase synchronization over stimulus repetitions of ASSR is assessed, other measures are being investigated. One of them is phase-amplitude coupling (PAC), which reflects the interactions between lower frequency phase and higher frequency amplitude. Considering that the number of studies assessing PAC during auditory steady-state stimulation has grown recently, in the present work, we aimed to perform a comprehensive overview of PAC methodological approaches in ASSR studies. We sought to evaluate the studies according to PAC analysis issues emphasized in empirical and theoretical PAC studies. Our work showed considerable variability in the methodology among the reviewed studies. Furthermore, the reviewed works address methodological issues and confounding factors of PAC relatively poorly and are characterized by insufficient descriptions of the applied approaches. Our review shows that systematic research of PAC in the context of ASSR is imperative in order to properly evaluate the presence of PAC during the auditory steady-state stimulation.
听觉稳态反应(ASSR)是一种以可控方式探测γ(>30Hz)活动的稳健方法。虽然通常会评估ASSR在刺激重复过程中的幅度和相位同步,但也在研究其他指标。其中之一是相位-幅度耦合(PAC),它反映了低频相位和高频幅度之间的相互作用。鉴于最近评估听觉稳态刺激期间PAC的研究数量有所增加,在本研究中,我们旨在对ASSR研究中的PAC方法进行全面概述。我们试图根据实证和理论PAC研究中强调的PAC分析问题来评估这些研究。我们的研究表明,在所审查的研究中,方法存在相当大的差异。此外,所审查的研究相对较差地解决了PAC的方法学问题和混杂因素,其特点是对所应用方法的描述不足。我们的综述表明,为了正确评估听觉稳态刺激期间PAC的存在,在ASSR背景下对PAC进行系统研究势在必行。