To evaluate the clinical precision, one-year survival, and complications of implant-supported full-arch fixed dental prostheses (ISFAFDPs) manufactured through a full-digital protocol, which involved intraoral scanning of the edentulous arch with a calibrated splinting framework (CSF; RingFix®; IOSFix Dental, Madrid, Spain) and computer-aided design and manufacturing of monolithic zirconia restorations.
This retrospective clinical study involved 37 patients (21 males and 16 females) aged 48-87 years (mean age: 68.8 ± 9.7 years) who had been restored with 45 ISFAFDPs manufactured using a full-digital protocol. The primary outcomes were the clinical precision of the ISFAFDPs and their survival and the incidence of complications at the one-year follow-up. The correction of errors in the position of the implants generated by the intraoral scan was computed using the CSF. The data were statistically analyzed.
At delivery, all ISFAFDPs were clinically precise, showing ideal passive fit on the implants, confirmed clinically and radiographically. No implants had been lost at the one-year follow-up. The incidence of prosthetic complications (4.4 %) was relatively low; one prosthesis broke, giving a restoration survival rate of 97.8 %.
Within the limits of this study, monolithic zirconia ISFAFDPs manufactured through intraoral scanning of the edentulous arches with a CSF were clinically precise, presenting a low incidence of complications at one year.
Using the CSF can improve the accuracy of digital full-arch implant scans, allowing the manufacture of clinically precise ISFAFDPs.
评估通过全数字流程制造的种植体支持的全牙弓固定义齿(ISFAFDPs)的临床精度、一年生存率和并发症情况,该流程包括使用校准夹板框架(CSF;RingFix®;IOSFix Dental,马德里,西班牙)对无牙弓进行口内扫描以及计算机辅助设计和制造整体式氧化锆修复体。
这项回顾性临床研究纳入了37例患者(21例男性和16例女性),年龄在48 - 87岁之间(平均年龄:68.8±9.7岁),他们接受了使用全数字流程制造的45例ISFAFDPs修复。主要观察指标为ISFAFDPs的临床精度、其生存率以及一年随访时并发症的发生率。使用CSF计算口内扫描产生的种植体位置误差的校正值。对数据进行统计学分析。
在交付时,所有ISFAFDPs在临床上都很精确,在种植体上显示出理想的被动就位,经临床和影像学证实。在一年随访时没有种植体丢失。修复并发症的发生率(4.4%)相对较低;有一个修复体断裂,修复体生存率为97.8%。
在本研究的范围内,通过使用CSF对无牙弓进行口内扫描制造的整体式氧化锆ISFAFDPs在临床上是精确的,一年时并发症发生率较低。
使用CSF可以提高全牙弓数字化种植扫描的准确性,从而制造出临床精确的ISFAFDPs。