Nakajima Tomohiro, Shibata Tsuyoshi, Iba Yutaka, Ogura Keishi, Kawaharada Nobuyoshi
Department of Cardiovascular Surgery, Sapporo Medical University, Sapporo, JPN.
Division of Radiology and Nuclear Medicine, Sapporo Medical University, Sapporo, JPN.
Cureus. 2025 Jan 14;17(1):e77408. doi: 10.7759/cureus.77408. eCollection 2025 Jan.
An 85-year-old man underwent abdominal aortic aneurysm (AAA) repair with a synthetic graft at age 48. Sac enlargement, likely due to an endoleak, was observed during follow-up, and covered stents were placed in the graft limbs at age 80. Despite this, the sac continued to enlarge, leading to a referral to our institution. Imaging revealed an endoleak from an uncovered graft section. An EXCLUDER® stent graft (W. L. Gore & Associates, Inc., Flagstaff, AZ) was placed to cover the graft entirely, resolving the endoleak. The patient was discharged on postoperative day 5. This case highlights the rare failure of a synthetic graft after 37 years.
一名85岁男性在48岁时接受了人工血管修复腹主动脉瘤手术。随访期间发现瘤体增大,可能是由于内漏所致,80岁时在人工血管分支处放置了覆膜支架。尽管如此,瘤体仍继续增大,遂转诊至我院。影像学检查显示未覆盖的人工血管段存在内漏。放置了EXCLUDER®覆膜支架(美国戈尔公司,亚利桑那州弗拉格斯塔夫)以完全覆盖人工血管,解决了内漏问题。患者术后第5天出院。该病例凸显了人工血管在37年后罕见的失败情况。