测量因除气导致的固定局部义齿变形。

Measurement of distortions in fixed partial dentures resulting from degassing.

作者信息

Bryant R A, Nicholls J I

出版信息

J Prosthet Dent. 1979 Nov;42(5):515-20. doi: 10.1016/0022-3913(79)90244-0.

Abstract
  1. During the degassing phase, fixed partial dentures removed immediately when the temperature reached 1,900 degrees F (1,038 degrees C) with soldered connectors do not distort more than those with cast connectors. While not tested, heat-soaking could be expected to cause a greater amount of distortion, especially for fixed and supported partial dentures having soldered connectors. 2. Use of custom-made sagger trays giving support to long-span fixed partial dentures at the ends and within the span is desirable for both degassing and porcelain firing, regardless of whether or not the connectors are cast or soldered. 3. The accumulative amount of possible distortion resulting from soldering, degassing, and porcelain firing may be clinically significant if precautions are not affected.
摘要
  1. 在除气阶段,当温度达到1900华氏度(1038摄氏度)时立即取出的带有焊接连接件的固定局部义齿,其变形程度不会比带有铸造连接件的固定局部义齿更大。虽然未进行测试,但热浸泡预计会导致更大程度的变形,尤其是对于带有焊接连接件的固定和支持式局部义齿。2. 对于除气和烤瓷来说,使用在两端和跨度内为长跨度固定局部义齿提供支撑的定制匣钵托盘是可取的,无论连接件是铸造的还是焊接的。3. 如果不采取预防措施,焊接、除气和烤瓷可能导致的累积变形量在临床上可能具有重要意义。