Williams M R, Mikulin T, Lemberger J, Hopkinson B R, Makin G S
Ann R Coll Surg Engl. 1985 May;67(3):152-5.
The 5 year results using polytetrafluoroethylene (PTFE-Gore-Tex) grafts mainly for superficial femoral occlusion have been reviewed. The majority of these grafts were inserted in an elderly poor risk group of patients with critical ischaemia of the lower limb. The overall cumulative patency at 2 years was 29% falling to 18% at 5 years. Further analyses were performed to take into account risk factors, namely, patient's age, diabetes, hypertension, continuation of smoking, peroperative angiographic findings and the site of the distal graft anastomosis. Peroperative angiographic run off was found to be the only risk factor significantly affecting the cumulative graft patency. The presence of diabetes was found to have a significant detrimental effect on limb salvage.
回顾了主要用于股浅动脉闭塞的聚四氟乙烯(PTFE-戈尔特斯)移植物的5年结果。这些移植物大多植入患有下肢严重缺血的老年高危患者群体。2年时的总体累积通畅率为29%,5年时降至18%。进行了进一步分析以考虑危险因素,即患者年龄、糖尿病、高血压、持续吸烟、术中血管造影结果以及远端移植物吻合部位。发现术中血管造影的流出情况是唯一显著影响移植物累积通畅率的危险因素。发现糖尿病的存在对肢体挽救有显著的不利影响。