Weinmann G G, Mitzner W
Crit Care Med. 1985 Jul;13(7):571-5. doi: 10.1097/00003246-198507000-00013.
We compared the effects of high-frequency oscillation (HFO) and conventional mechanical ventilation (CMV) on dynamic lung compliance (Cdyn), venous admixture (Qsp/Qt), cardiac output, and total lung resistance (RL) in seven mongrel dogs with histamine-induced lung injury. Baseline measurements during CMV were followed by iv infusion of histamine at 100 micrograms/min. Cdyn, Qsp/Qt, cardiac output, and RL were measured in triplicate during CMV and then during HFO. Subsequently, at least one complete set of measurements was recorded again on CMV. During HFO, animals were ventilated at 15 Hz with a tidal volume of 70 to 80 ml. CMV was delivered at 15 to 18 breath/min with a tidal volume of 15 ml/kg. Histamine infusion produced a marked fall in Cdyn, a variable rise in RL, an inconsistent but usually progressive rise in Qsp/Qt, and hypotension. A period of ventilation with HFO made no difference in the Cdyn, Qsp/Qt, or cardiac output changes produced by histamine infusion.
我们比较了高频振荡通气(HFO)和传统机械通气(CMV)对7只因组胺诱导肺损伤的杂种犬的动态肺顺应性(Cdyn)、静脉血掺杂(Qsp/Qt)、心输出量和总肺阻力(RL)的影响。在CMV期间进行基线测量,随后以100微克/分钟的速度静脉输注组胺。在CMV期间和随后的HFO期间,对Cdyn、Qsp/Qt、心输出量和RL进行了三次测量。随后,再次在CMV上记录至少一组完整的测量值。在HFO期间,动物以15赫兹的频率通气,潮气量为70至80毫升。CMV以15至18次/分钟的频率进行,潮气量为15毫升/千克。组胺输注导致Cdyn显著下降,RL有不同程度的升高,Qsp/Qt有不一致但通常呈进行性的升高,以及低血压。一段时间的HFO通气对组胺输注引起的Cdyn、Qsp/Qt或心输出量变化没有影响。