Gammans R E, Kerns E H, Bullen W W, Covington R R, Russell J W
J Chromatogr. 1985 May 3;339(2):303-12. doi: 10.1016/s0378-4347(00)84657-5.
A plasma assay method for trazodone and a 2H4 analogue is described which uses gas chromatography--electron-impact selected-ion monitoring mass spectrometry. Etoperidone is used as an internal standard. The analytes are extracted from basic medium into n-butyl chloride, then back extracted into aqueous 0.1 M hydrochloric acid. The aqueous layer is made basic and re-extracted with n-butyl chloride. The solvent is reduced under nitrogen at 35 degrees C and the residue is redissolved in toluene for gas chromatographic--mass spectrometric analysis. The ions monitored are m/z 231, 235, and 225 for trazodone, [2H4] trazodone and etoperidone, respectively. Quantitation is in the range 40-1000 ng/ml with acceptable precision and accuracy. The method is suitable for biopharmaceutical studies.
描述了一种用于曲唑酮及其2H4类似物的血浆分析方法,该方法采用气相色谱 - 电子轰击选择离子监测质谱法。依托哌酮用作内标。分析物从碱性介质中萃取到正丁基氯中,然后反萃取到0.1 M盐酸水溶液中。将水层调至碱性并用正丁基氯再次萃取。在35℃下于氮气氛围中浓缩溶剂,残留物重新溶解于甲苯中用于气相色谱 - 质谱分析。监测的离子分别为曲唑酮的m/z 231、[2H4]曲唑酮的m/z 235和依托哌酮的m/z 225。定量范围为40 - 1000 ng/ml,具有可接受的精密度和准确度。该方法适用于生物制药研究。