Suppr超能文献

一种无需飞秒激光的角膜同种异体基质内环形片的手动技术。

A Manual Technique for Corneal Allogeneic Intrastromal Ring Segments Without a Femtosecond Laser.

作者信息

Hayashi Takahiko, Hara Yusuke, Sunouchi Chihiro, Yuda Kentaro, Kojima Takashi, Kato Naoko, Cronin Brendan, Yamagami Satoru

机构信息

Department of Ophthalmology, Nihon University School of Medicine, Itabashi, Tokyo, Japan.

Department of Visual Sciences, Nihon University School of Medicine, Itabashi, Tokyo, Japan.

出版信息

Cornea. 2025 Mar 19;44(8):1053-1057. doi: 10.1097/ICO.0000000000003853.

Abstract

PURPOSE

To evaluate the outcomes of corneal allogeneic intrastromal ring segments (CAIRS) using a simplified manual technique for treating keratoconus.

METHODS

This prospective case series included 5 eyes from 5 patients with keratoconus (4 males, 1 female, mean age 32.5 ± 10.6 years) treated with manual CAIRS. Surgeries were performed under local anesthesia by a single surgeon. An intrastromal pocket for donor tissue implantation was manually created using a spatula, and donor corneas were prepared using a Jacobs CAIRS trephine. Corneal parameters, including higher-order aberrations, coma, and spherical aberrations at a 6 mm diameter, were measured using optical coherence tomography (CASIA SS-1000, Tomey, Japan). Anterior and posterior corneal indices, subjective refractive power, cylinder, spherical equivalent, best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR]), and central corneal thickness. Intra- and postoperative complications were also analyzed.

RESULTS

Over a mean follow-up of 6.4 ± 2.9 months, no complications occurred. BCVA improved from 0.74 ± 0.44 logMAR preoperatively to 0.19 ± 0.66 logMAR ( P = 0.043). The maximum keratometry (Kmax) value decreased from 63.6 ± 8.3D preoperatively to 59.6 ± 6.8D postoperatively ( P = 0.043). Spherical equivalent improved from -11.2 ± 5.8D to -5.3 ± 3.1D ( P = 0.043), and astigmatism reduced from -5.0 ± 3.4D to -3.3 ± 2.9D. Total corneal higher-order aberrations decreased from 5.6 ± 1.6D to 4.2 ± 1.6D postoperatively ( P = 0.043).

CONCLUSIONS

Manual CAIRS is an effective treatment when a femtosecond laser is not available.

摘要

目的

采用简化的手工技术评估同种异体角膜基质内环形片段(CAIRS)治疗圆锥角膜的效果。

方法

该前瞻性病例系列包括5例圆锥角膜患者的5只眼(4例男性,1例女性,平均年龄32.5±10.6岁),采用手工CAIRS治疗。手术由同一位外科医生在局部麻醉下进行。使用刮铲手工制作供体组织植入的基质内口袋,并使用雅各布斯CAIRS环钻制备供体角膜。使用光学相干断层扫描(CASIA SS - 1000,日本多美)测量角膜参数,包括6毫米直径处的高阶像差、彗差和球差。测量前后角膜指数、主观屈光力、柱镜、等效球镜、最佳矫正视力(BCVA;最小分辨角对数[logMAR])和中央角膜厚度。还分析了术中及术后并发症。

结果

平均随访6.4±2.9个月,未发生并发症。BCVA从术前的0.74±0.44 logMAR提高到0.19±0.66 logMAR(P = 0.043)。最大角膜曲率(Kmax)值从术前的63.6±8.3D降至术后的59.6±6.8D(P = 0.043)。等效球镜从 - 11.2±5.8D改善至 - 5.3±3.1D(P = 0.043),散光从 - 5.0±3.4D降至 - 3.3±2.9D。术后角膜总高阶像差从5.6±1.6D降至4.2±1.6D(P = 0.043)。

结论

在没有飞秒激光的情况下,手工CAIRS是一种有效的治疗方法。