Kucharczyk W, Lemme-Pleghos L, Uske A, Brant-Zawadzki M, Dooms G, Norman D
Radiology. 1985 Aug;156(2):383-9. doi: 10.1148/radiology.156.2.4011900.
Twenty-four patients with 29 cerebrovascular malformations were evaluated with a combination of computed tomography (CT), angiography, and magnetic resonance (MR) imaging. Characteristics of the malformations on MR images were reviewed retrospectively, and a comparative evaluation of MR and CT images was made. Of 14 angiographically evident malformations, 13 intra-axial lesions were detected on both CT and MR images, and one dural malformation gave false-negative results on both modalities. The appearance of parenchymal lesions on MR images closely mirrored characteristic CT findings. Calcific foci were difficult to separate from vessels on both images. Clot was more easily identified on MR images. In the detection of 15 angiographically occult malformations, CT proved more sensitive when focal calcification was the only evidence of their presence. MR study failed to detect two small supratentorial lesions evidenced by faint calcifications on CT scans. In two patients, MR images showed small hemorrhages not detectable by CT, and MR provided strong evidence for the diagnosis of hematoma for 12 lesions. Angiographically evident malformations have a highly characteristic appearance on MR images. MR may be more sensitive than CT in the detection of small hemorrhagic foci associated with cryptic arteriovenous malformations and may add specificity in the diagnosis of occult malformations in some cases, but MR is less sensitive than CT for the detection of small calcified malformations.
对24例患有29处脑血管畸形的患者进行了计算机断层扫描(CT)、血管造影和磁共振(MR)成像联合评估。回顾性分析了MR图像上畸形的特征,并对MR图像和CT图像进行了对比评估。在14处血管造影显示明显的畸形中,CT和MR图像均检测到13处轴内病变,1处硬脑膜畸形在两种检查方式下均呈假阴性结果。MR图像上实质病变的表现与CT的典型表现密切相似。两种图像上钙化灶都难以与血管区分开。MR图像上更容易识别血栓。在检测15处血管造影隐匿性畸形时,当局灶性钙化是其存在的唯一证据时,CT显示更敏感。MR检查未能检测到CT扫描显示微弱钙化的2处幕上小病变。在2例患者中,MR图像显示了CT无法检测到的小出血,并且MR为12处病变的血肿诊断提供了有力证据。血管造影显示明显的畸形在MR图像上有高度特征性表现。在检测与隐匿性动静脉畸形相关的小出血灶方面,MR可能比CT更敏感,并且在某些情况下对隐匿性畸形的诊断可能增加特异性,但在检测小钙化畸形方面,MR比CT敏感性低。