Suppr超能文献

三维颌间骨骼评估的新方法:ANB角与Wits平分线评估之间的相关性

Novel approach to three-dimensional intermaxillary skeletal assessment : Correlation between the ANB angle and the bisector Wits appraisal.

作者信息

Serafin M, Baldini B, Rossi O, Perrotti G, Caprioglio A

机构信息

Department of Biomedical Sciences for Health, University of Milan, Milan, Italy.

Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy.

出版信息

J Orofac Orthop. 2025 Mar 31. doi: 10.1007/s00056-025-00583-0.

Abstract

PURPOSE

The present study aimed to compare and correlate the ANB angle with the bisector Wits appraisal for a three-dimensional (3D) assessment of the maxillomandibular sagittal relationship using a cone beam computed tomography (CBCT) dataset.

METHODS

After outlier removal, 351 CBCT scans were chosen based on inclusion criteria (high quality, full-cranium field of view [FOV], slice thickness 150-300 μm) and analyzed using 3DSlicer software (Brigham and Women's Hospital, Boston, MA, USA, version 5.2.2). Eight anatomical landmarks were manually annotated, identified on axial views, and confirmed on the rendered volume image. The coordinates of each landmark were exported and the ANB (°) and bisector-Wits (mm) measurements were constructed. Dahlberg's D tested the intraobserver reliability and two-sample Kolmogorov-Smirnov test was executed to assess normality and to select the subsequent tests. Spearman's rank correlation coefficient (ρ) was utilized to correlate the angular (ANB) and linear (bisector-Wits) measurements, whereas the Siegel estimator for nonparametric linear regression was employed to establish norm values by the correlation equation. Significance was set at p < 0.05 with correlation coefficients exceeding ρ > 0.70 deemed clinically relevant.

RESULTS

High (ρ = 0.773) and statistically significant (p < 0.001) correlations between the ANB and bisector-Wits measurements were found. The obtained equation was the following: bisector-Wits = 1.06 × ANB - 6.32. Therefore, the obtained rounded norm range for bisector-Wits for skeletal class I sagittal relationship was determined to be from -6.3 to -2.1 mm (-4.2 ± 2.1 mm). Values less than -6.3 mm correspond to a class III, whereas greater than -2.1 mm correspond to a class II skeletal relationship.

CONCLUSION

The study revealed a statistically significant correlation between the ANB and bisector-Wits. From a 3D perspective, the bisector-Wits represents a reliable parameter to assess maxilla-mandibular skeletal discrepancies instead of the ANB angle, also adhering to radioprotection principles by limiting the FOV to the maxillary complex only and potentially reducing the radiation exposure in CBCT-based cephalometry.

摘要

目的

本研究旨在使用锥形束计算机断层扫描(CBCT)数据集,比较ANB角与平分线Wits评估值,并将二者关联起来,以对上下颌矢状关系进行三维(3D)评估。

方法

在去除异常值后,根据纳入标准(高质量、全颅视野[FOV]、层厚150 - 300μm)选择了351例CBCT扫描图像,并使用3DSlicer软件(美国马萨诸塞州波士顿布莱根妇女医院,版本5.2.2)进行分析。手动标注了八个解剖标志点,在轴位视图上识别并在三维重建图像上确认。导出每个标志点的坐标,并构建ANB(°)和平分线 - Wits(mm)测量值。Dahlberg's D检验观察者内可靠性,并执行双样本柯尔莫哥洛夫 - 斯米尔诺夫检验以评估正态性并选择后续检验。使用斯皮尔曼等级相关系数(ρ)来关联角度(ANB)和线性(平分线 - Wits)测量值,而采用非参数线性回归的西格尔估计器通过相关方程建立正常值。显著性设定为p < 0.05,相关系数超过ρ > 0.70被认为具有临床相关性。

结果

发现ANB与平分线 - Wits测量值之间存在高度(ρ = 0.773)且具有统计学意义(p < 0.001)的相关性。得到的方程如下:平分线 - Wits = 1.06×ANB - 6.32。因此,确定骨骼I类矢状关系的平分线 - Wits的取整正常范围为 - 6.3至 - 2.1mm(-4.2±2.1mm)。小于 - 6.3mm的值对应III类,而大于 - 2.1mm的值对应II类骨骼关系。

结论

该研究揭示了ANB与平分线 - Wits之间具有统计学意义的相关性。从三维角度来看,平分线 - Wits是评估上颌 - 下颌骨骼差异的可靠参数,而非ANB角,并且通过仅将视野限制在上颌复合体,也遵循了放射防护原则,有可能减少基于CBCT的头影测量中的辐射暴露。