Yu Mingyi, Liu Chang, Lee Isabelle Xin Yu, Hsu Victor Wei-Tse, Wong Regina Kay Ting, Anam Ansa, Lim Rong, Mehta Jodhbir S, Liu Yu-Chi
Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Singapore, S169856, Singapore.
Department of Ophthalmology, MTI Khyber Teaching Hospital, Peshawar, Pakistan.
Eye Vis (Lond). 2025 Apr 1;12(1):12. doi: 10.1186/s40662-025-00429-1.
To investigate and compare the corneal denervation, tear neuromediators, and ocular surface changes following corneal lenticule extraction for advanced refractive correction (CLEAR) versus small incision lenticule extraction (SMILE).
In this randomized clinical trial, 19 patients were randomized to undergo CLEAR in one eye and SMILE in the other eye. Ocular surface assessments, in vivo confocal microscopy for seven corneal nerve parameters, four corneal dendritic cell parameters, three corneal epithelial parameters, and tear neuromediator analysis were performed preoperatively and 1, 3, 6 and 12 months postoperatively.
There were no significant differences in all ocular surface assessments between CLEAR and SMILE throughout postoperative 1 year. CLEAR and SMILE led to significant and comparable reductions of corneal nerve fiber density (CNFD), nerve branch density, total branch density, nerve fiber length, area, and fiber fractal dimension, which did not restore even at 1 year. The reduction in CNFD was significantly correlated with the corrected spherical equivalent in both surgical types. Although post-SMILE eyes had significantly higher nerve growth factor concentrations at 1 month, there was no significant difference in substance P and calcitonin gene-related peptide (CGRP) concentrations between SMILE and CLEAR.
CLEAR and SMILE had comparable effects on ocular surface, corneal denervation and postoperative neuroinflammation. Corneal nerve metrics did not restore even at 1 year for both procedures.
ClinicalTrials.gov NCT06774651, registration on 14 January 2025, https://clinicaltrials.gov/study/NCT06774651 .
研究并比较用于高度屈光不正矫正的角膜透镜取出术(CLEAR)与小切口透镜取出术(SMILE)后的角膜去神经支配、泪液神经介质及眼表变化。
在这项随机临床试验中,19例患者被随机分配,一只眼睛接受CLEAR手术,另一只眼睛接受SMILE手术。术前及术后1、3、6和12个月进行眼表评估、体内共聚焦显微镜检查以评估七个角膜神经参数、四个角膜树突状细胞参数、三个角膜上皮参数,并进行泪液神经介质分析。
在术后1年期间,CLEAR和SMILE在所有眼表评估方面均无显著差异。CLEAR和SMILE均导致角膜神经纤维密度(CNFD)、神经分支密度、总分支密度、神经纤维长度、面积和纤维分形维数显著且相当程度的降低,即使在1年后也未恢复。两种手术方式中,CNFD的降低均与矫正球镜等效度显著相关。虽然SMILE术后1个月时眼内神经生长因子浓度显著更高,但SMILE和CLEAR之间的P物质和降钙素基因相关肽(CGRP)浓度并无显著差异。
CLEAR和SMILE在眼表、角膜去神经支配及术后神经炎症方面具有相似的效果。两种手术方式的角膜神经指标即使在1年后也未恢复。
ClinicalTrials.gov NCT06774651,于2025年1月14日注册,https://clinicaltrials.gov/study/NCT06774651 。