Morita Ryo, Abo Daisuke, Fujii Takaaki, Kinota Naoya, Kato Daisuke, Yamasaki Kouji, Kanaya Motoma, Harada Taisuke, Sugita Osamu, Kawamura Norio, Taketomi Akinobu, Kudo Kohsuke
Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, N-14, W-5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan.
Department of Dental Radiology, Hokkaido University Hospital, N-14, W-5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan.
Radiol Case Rep. 2025 Mar 18;20(6):2813-2819. doi: 10.1016/j.radcr.2025.02.080. eCollection 2025 Jun.
Patient-specific vascular models enhance preoperative planning in interventional radiology, particularly in complex and anatomically challenging cases. This report presents two cases of complex aneurysm coil embolization in which three-dimensional, printed, patient-specific vascular hollow models were key to selecting optimal catheters, leading to successful interventions. Preoperative simulations with these models facilitated preselection of the optimal catheter, minimizing the need for intraoperative catheter exchange and reducing the time required for catheter engagement and placement. This approach improves procedural efficiency and outcomes by ensuring a smoother workflow.
针对患者的血管模型可增强介入放射学中的术前规划,尤其是在复杂且解剖结构具有挑战性的病例中。本报告介绍了两例复杂动脉瘤弹簧圈栓塞病例,其中三维打印的针对患者的血管空心模型是选择最佳导管的关键,从而实现了成功的干预。使用这些模型进行术前模拟有助于预先选择最佳导管,最大限度地减少术中更换导管的需求,并减少导管插入和放置所需的时间。这种方法通过确保更顺畅的工作流程来提高手术效率和效果。