Suppr超能文献

中耳光学相干断层扫描与计算机断层扫描的融合

Fusion of Middle Ear Optical Coherence Tomography and Computed Tomography.

作者信息

Wang Junzhe, Couvreur Floor, Farrell Joshua D, Ghedia Reshma, Shoman Nael, Morris David P, Adamson Robert B A

机构信息

School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.

Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, Dalhousie University, Halifax, Nova Scotia, Canada.

出版信息

JAMA Otolaryngol Head Neck Surg. 2025 May 1;151(5):476-484. doi: 10.1001/jamaoto.2025.0043.

Abstract

IMPORTANCE

Middle ear optical coherence tomography (OCT) imaging in patients has not previously been directly compared with a standard of care clinical 3-dimensional imaging technology, such as computed tomography (CT).

OBJECTIVE

To qualitatively compare the capabilities of middle ear OCT with CT in normal and pathological ears on representative slices in coregistered OCT and CT datasets.

DESIGN, SETTING, AND PARTICIPANTS: This case series included 3 patients and 3 ears: 1 normal middle ear, 1 ear affected by traumatic injury, and 1 ear with cholesteatoma. The ears were imaged with both OCT and high-resolution clinical temporal bone CT. Participants were drawn from the patient population of a tertiary otology clinic. CT and OCT images were aligned using rigid coregistration with manual landmark selection. Data were collected from January 2022 to April 2023, and data were analyzed from February 2022 to December 2023.

MAIN OUTCOMES AND MEASURES

Images were analyzed qualitatively for field of view (FOV), resolution, shadowing, artifacts, soft tissue and bony tissue contrast, and presentation of diagnostically important features.

RESULTS

In the 3 imaged ears, OCT was capable of visualizing many of the important features indicative of middle ear pathology. Compared with CT, OCT exhibited a limited FOV largely confined to the mesotympanum and subject to shadowing from bony structures. However, OCT could resolve soft tissue features that were not readily apparent in the CT images to have a higher resolution than CT and to provide excellent anatomical fidelity with CT, which allowed OCT images to be accurately coregistered with CT images.

CONCLUSIONS AND RELEVANCE

In this case series, while OCT was not capable of replacing CT due to its limited FOV and inability to image through thick bony tissues, it visualized signs of pathology, including some soft tissue features, that are difficult to visualize with CT. Given OCT's ability to image in real time, its compatibility with in-office imaging, and its lack of ionizing radiation, it may, despite its limitations compared with CT, be an appealing imaging modality for many applications in middle ear diagnostics.

摘要

重要性

此前尚未将患者中耳光学相干断层扫描(OCT)成像与计算机断层扫描(CT)等临床三维成像标准技术进行直接比较。

目的

在配准的OCT和CT数据集中的代表性切片上,定性比较正常耳和病理耳中中耳OCT与CT的成像能力。

设计、设置和参与者:该病例系列包括3名患者和3只耳朵:1只正常中耳、1只受外伤影响的耳朵和1只患有胆脂瘤的耳朵。对这些耳朵进行了OCT和高分辨率临床颞骨CT成像。参与者来自一家三级耳科诊所的患者群体。使用手动地标选择的刚性配准对CT和OCT图像进行对齐。数据收集于2022年1月至2023年4月,数据分析于2022年2月至2023年12月。

主要结局和指标

对图像进行定性分析,评估视野(FOV)、分辨率、阴影、伪影、软组织和骨组织对比度以及诊断重要特征的呈现。

结果

在3只成像耳朵中,OCT能够显示许多指示中耳病理的重要特征。与CT相比,OCT的视野有限,主要局限于中鼓室,且会受到骨结构阴影的影响。然而,OCT能够分辨出CT图像中不易显现的软组织特征,分辨率高于CT,并能与CT提供出色的解剖保真度,这使得OCT图像能够与CT图像精确配准。

结论和意义

在本病例系列中,虽然由于视野有限且无法穿透厚骨组织成像,OCT无法替代CT,但它能够显示出病理迹象,包括一些CT难以显示的软组织特征。鉴于OCT能够实时成像、与门诊成像兼容且无电离辐射,尽管与CT相比存在局限性,但它可能是中耳诊断中许多应用的一种有吸引力的成像方式。

相似文献

1
Fusion of Middle Ear Optical Coherence Tomography and Computed Tomography.
JAMA Otolaryngol Head Neck Surg. 2025 May 1;151(5):476-484. doi: 10.1001/jamaoto.2025.0043.
3
Optical coherence tomography otoscope for imaging of tympanic membrane and middle ear pathology.
J Biomed Opt. 2024 Aug;29(8):086005. doi: 10.1117/1.JBO.29.8.086005. Epub 2024 Aug 20.
5
6
Improved Assessment of Middle Ear Recurrent Cholesteatomas Using a Fusion of Conventional CT and Non-EPI-DWI MRI.
AJNR Am J Neuroradiol. 2019 Sep;40(9):1546-1551. doi: 10.3174/ajnr.A6141. Epub 2019 Aug 14.
7
Improved middle-ear soft-tissue visualization using synchrotron radiation phase-contrast imaging.
Hear Res. 2017 Oct;354:1-8. doi: 10.1016/j.heares.2017.08.001. Epub 2017 Aug 5.
9
The Dresden in vivo OCT dataset for automatic middle ear segmentation.
Sci Data. 2024 Feb 26;11(1):242. doi: 10.1038/s41597-024-03000-0.
10
Non-rigid point cloud registration for middle ear diagnostics with endoscopic optical coherence tomography.
Int J Comput Assist Radiol Surg. 2024 Jan;19(1):139-145. doi: 10.1007/s11548-023-02960-9. Epub 2023 Jun 17.

本文引用的文献

1
Optical coherence tomography otoscope for imaging of tympanic membrane and middle ear pathology.
J Biomed Opt. 2024 Aug;29(8):086005. doi: 10.1117/1.JBO.29.8.086005. Epub 2024 Aug 20.
3
OCT-based intra-cochlear imaging and 3D reconstruction: ex vivo validation of a robotic platform.
Int J Comput Assist Radiol Surg. 2024 May;19(5):917-927. doi: 10.1007/s11548-024-03081-7. Epub 2024 Mar 4.
4
The Dresden in vivo OCT dataset for automatic middle ear segmentation.
Sci Data. 2024 Feb 26;11(1):242. doi: 10.1038/s41597-024-03000-0.
5
Geometrically accurate real-time volumetric visualization of the middle ear using optical coherence tomography.
Biomed Opt Express. 2023 Jun 7;14(7):3152-3171. doi: 10.1364/BOE.488845. eCollection 2023 Jul 1.
6
Non-rigid point cloud registration for middle ear diagnostics with endoscopic optical coherence tomography.
Int J Comput Assist Radiol Surg. 2024 Jan;19(1):139-145. doi: 10.1007/s11548-023-02960-9. Epub 2023 Jun 17.
7
Live 4D-OCT denoising with self-supervised deep learning.
Sci Rep. 2023 Apr 8;13(1):5760. doi: 10.1038/s41598-023-32695-1.
8
microstructural investigation of the human tympanic membrane by endoscopic polarization-sensitive optical coherence tomography.
J Biomed Opt. 2023 Dec;28(12):121203. doi: 10.1117/1.JBO.28.12.121203. Epub 2023 Mar 29.
9
Evaluation of the Impact of Optical Coherence Tomography on Pediatrician Otologic Examination Judgment.
OTO Open. 2023 Mar 1;7(1):e41. doi: 10.1002/oto2.41. eCollection 2023 Jan-Mar.