Suppr超能文献

Development of mass spectrometric methods for determination of desoxycorticosterone pivalate and its esterase product in canine serum.

作者信息

Lehner A F, Zyskowski Justin, Buchweitz J P, Langlois D K

机构信息

Veterinary Diagnostic Laboratory, Section of Toxicology, College of Veterinary Medicine, Michigan State University, East Lansing, MI, USA.

Department of Pathobiology and Diagnostic Investigation, College of Veterinary Medicine, Michigan State University, East Lansing, MI, USA.

出版信息

Toxicol Mech Methods. 2025 Sep;35(7):729-741. doi: 10.1080/15376516.2025.2489026. Epub 2025 Apr 14.

Abstract

Hypoadrenocorticism is a serious condition in dogs that results from autoimmune adrenalitis and depletion of mineralocorticoids and glucocorticoids. Affected dogs respond well to glucocorticoid supplementation and treatment with the synthetic mineralocorticoid desoxycorticosterone pivalate (DOCP). DOCP injected once monthly resolves serum Na/K abnormalities and normalizes water balance, but therapy is expensive. Cost abatement involves prolongation of the 30-day dosage interval or decreasing the 2.2 mg/kg dosage. These approaches are not based on DOCP pharmacokinetics. A full assessment of the practicality of either approach would benefit from understanding drug pharmacokinetics, requiring measurement of DOCP and its esterase product desoxycorticosterone (DOC) in canine serum while avoiding toxic endpoints from overdosing. Mass spectrometric methods were developed including gas chromatography-tandem mass spectrometry of DOCP and DOC-methoxime trimethylsilyl derivatives, an approach sensitive to 2 ng/mL. Greater sensitivity was desired, so liquid chromatography-tandem mass spectrometry (LC-MS/MS) with ESI+ ionization was investigated. Supported liquid extraction was devised for serum with recoveries ∼100%. The LC-MS/MS method was validated for linearity, precision, accuracy and limits of detection (0.029 and 0.019 ng/mL for DOC and DOCP, respectively). A pilot experiment with DOCP-treated hypoadrenocorticism dogs over one-month revealed DOC baseline values as 0.183+/-0.090 ng/mL, which increased to the 1.0 - 2.2 ng/mL range. DOCP was not visible in any samples suggesting 100% conversion. Halving the dosage to 1.1 mg/kg still showed clear increases over the DOC baseline. MS fragmentation involved ring cleavages, dehydrations and double-charged fragments. The methodology was robust and suitable for studying DOC/DOCP pharmacokinetics in future studies of hypoadrenocorticism dogs.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验