Noa-Yarasca Socorro, López-Flores Ana
Division de Rehabilitacion Oral, Facultad de Ciencias de la Salud, Carrera de Estomatologia, Departamento de Posgrado Universidad Cientifica del Sur. Lima, Peru.
Rev Cient Odontol (Lima). 2025 Mar 3;13(1):e228. doi: 10.21142/2523-2754-1301-2025-228. eCollection 2025 Jan-Mar.
To evaluate the flexural strength of three dental resin cements.
Sixty bars measuring 25x2x2 mm were made of RelyX-U200, Relyx Universal and Duo-Link Universal cements. These bars were divided into 3 groups according to brand (n=20) and were kept in distilled water for 24 hours at 37ºC. The 3-point bending test was carried out, according to ISO 4049, in a universal testing machine at a speed of 0.5 mm/min until fracture. Statistical analysis was performed with the Python statistical package, using the one-way Anova test and Tukey's multiple comparisons test with a confidence level of 95%.
Duo-Link Universal cement obtained the highest average with respect to flexural strength (104.7±7.8 MPa). Statistically significant differences were found between the three groups (p< 0.001). These differences were present between Relyx Universal - Duo-Link Universal (p<.001) and Duo-Link Universal - RelyX U200 (p< .001) cements, while no statistically significant differences were found between Relyx Universal and RelyX U200 cements.
Duo-Link Universal cement presents greater flexural strength compared to RelyX-U200 and Relyx Universal cements. The results indicate that Duo-Link Universal is ideal for restorations requiring high flexural strength, offering greater clinical durability, especially in areas of greater functional load and extensive restorations such as indirect prostheses or posts.
评估三种牙科树脂水门汀的抗弯强度。
用RelyX-U200、RelyX Universal和Duo-Link Universal水门汀制作60根尺寸为25×2×2mm的试条。这些试条根据品牌分为3组(每组n = 20),并在37℃的蒸馏水中保存24小时。根据ISO 4049标准,在万能试验机上以0.5mm/min的速度进行三点弯曲试验,直至试条断裂。使用Python统计软件包进行统计分析,采用单因素方差分析和Tukey多重比较检验,置信水平为95%。
Duo-Link Universal水门汀的抗弯强度平均值最高(104.7±7.8MPa)。三组之间存在统计学显著差异(p < 0.001)。这些差异存在于RelyX Universal - Duo-Link Universal(p < 0.001)和Duo-Link Universal - RelyX U200(p < 0.001)水门汀之间,而RelyX Universal和RelyX U200水门汀之间未发现统计学显著差异。
与RelyX-U200和RelyX Universal水门汀相比,Duo-Link Universal水门汀具有更高的抗弯强度。结果表明,Duo-Link Universal适用于需要高抗弯强度的修复体,具有更高的临床耐久性,特别是在功能负荷较大的区域以及间接修复体或桩等大面积修复中。