Bukvic Hristina, Schenk Nicole, Hinz Sebastian, Schimmel Martin, Enkling Norbert, Abou-Ayash Samir
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Division of Gerodontology and Removable Prosthodontics, University of Geneva, Geneva, Switzerland.
Int J Implant Dent. 2025 Apr 17;11(1):32. doi: 10.1186/s40729-025-00620-y.
To report the evaluation of in vivo retention forces after replacement of O-rings in one-piece mini dental implants (MDIs), retaining mandibular implant overdentures (IODs) with ball/O-ring attachments during 10 years assessed.
Twenty patients received new complete dentures, which were converted into IODs through stabilization with four MDIs (Condent GmbH; diameter: 1.8 mm) placed in the interforaminal region. Retention forces were measured at the male and female parts at baseline, 5, and 10 years using a validated strain gauge. Fourteen patients completed the 10-year follow-up.
After 10 years, a minor but significant reduction in retention force was observed in the male part of the implant at position 44. In contrast, neither the male part at the other implant positions nor the female part at any position showed a significant decrease in retention force compared to baseline. After replacement of the O-ring inserts, baseline values could be restored and no significant changes in retention forces were observed at the 10-year follow-up. No difference in anterior and posterior implants could be determined.
Initial retention forces of mandibular IODs supported by four MDIs can be reestablished by replacing the O-rings with pristine ones after 10 years, with stable retention forces at both the male and female parts throughout the functional period, with no discernible differences between anterior and posterior implants.
报告在评估为期10年的使用球/O形环附件固位下颌种植覆盖义齿(IOD)的一体式微型牙种植体(MDI)中更换O形环后的体内固位力。
20名患者接受了新的全口义齿,通过在孔间区域植入4枚MDI(Condent GmbH;直径:1.8毫米)进行稳定化处理,将其转换为IOD。在基线、5年和10年时,使用经过验证的应变仪测量雄性和雌性部件处的固位力。14名患者完成了10年的随访。
10年后,在44号位置的种植体雄性部件处观察到固位力有轻微但显著的降低。相比之下,与基线相比,其他种植体位置的雄性部件或任何位置的雌性部件的固位力均未显示出显著下降。更换O形环插入件后,基线值得以恢复,在10年随访时未观察到固位力有显著变化。前后部种植体之间未发现差异。
在10年后用全新的O形环替换,可以重新建立由4枚MDI支持的下颌IOD的初始固位力,在整个功能期内雄性和雌性部件的固位力均稳定,前后部种植体之间无明显差异。