Suppr超能文献

分叉型主动脉移植物的通畅率:同一患者中机织与针织假体的对比分析。

Patency rate of bifurcated aortic grafts: comparative analysis of woven versus knitted prostheses in the same patient.

作者信息

Robicsek F, Daugherty H K, Cook J C, Selle J G, Hess P J, Burtoft J, Lawhorn R

出版信息

Ann Thorac Surg. 1985 Aug;40(2):172-4. doi: 10.1016/s0003-4975(10)60013-6.

Abstract

To investigate the difference in patency rate between woven and knitted aortofemoral or aortoiliac prosthetic grafts, a special vascular prosthesis was manufactured with one limb of the graft knitted and the other, woven. The prosthesis was implanted in 143 consecutive patients with occlusive aortoiliac arteriosclerotic disease or aneurysms. Detailed statistical analysis failed to reveal any difference in the patency rate between the woven and knitted limbs of the grafts during an observation period ranging from one month to two years.

摘要

为研究编织型与针织型主股或主髂人工血管通畅率的差异,制作了一种特殊的血管假体,其移植血管的一个分支为针织型,另一个为编织型。该假体被植入143例连续性主髂动脉硬化闭塞症或动脉瘤患者体内。在1个月至2年的观察期内,详细的统计分析未能揭示移植血管的编织型分支与针织型分支在通畅率上存在任何差异。