Suppr超能文献

增强滤波器对使用手持式X射线装置获得的X光片中近端龋损诊断的影响。

Influence of enhancement filters on the diagnosis of proximal caries lesions in radiographs obtained with a handheld X-ray unit.

作者信息

Ruiz Débora Costa, Oliveira Matheus L, Gaêta-Araujo Hugo, Freitas Deborah Queiroz, Haiter-Neto Francisco

机构信息

Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Av. Limeira, 901, Areião, Piracicaba, SP, 13414-903, Brazil.

Department of Stomatology, Public Health, and Forensic Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil.

出版信息

Oral Radiol. 2025 Apr 25. doi: 10.1007/s11282-025-00823-4.

Abstract

OBJECTIVE

To assess the influence of enhancement filters on the diagnosis of proximal caries lesions in radiographs obtained with a handheld X-ray unit.

METHODS

Radiographs of 40 human teeth exhibiting white spots or enamel discolorations were obtained with an Eagle X-ray handheld unit (Alliage, São Paulo, Brazil) configured at 2.5 mA, 60 kVp, and 0.45 s of exposure time. Two digital imaging systems (VistaScan and Digora Toto) were used for radiographic acquisition. A total of 12 enhancement filters--six available in each system--were applied to the radiographs. A total of five dentomaxillofacial radiologists blinded to the filtering condition independently evaluated the radiographs for the presence of caries lesions using a 5-point scale. The area under the receiver operating characteristic curve, sensitivity, and specificity were determined based on the examiners' responses and were compared across the filters tested using one-way analysis of variance, with a significance level of 5%. The weighted Kappa index was used to assess both intra- and inter-examiner agreements in the diagnosis of proximal caries lesions.

RESULTS

Applying the enhancement filters tested did not influence the diagnostic metrics of proximal caries lesions in radiographs obtained using a handheld X-ray unit (p > 0.05). While the intra-examiner agreements were substantial, the inter-examiner agreements ranged from fair to moderate.

CONCLUSIONS

The enhancement filters available in the VistaScan and Digora Toto digital systems did not impact the diagnostic accuracy of proximal caries lesions in radiographs obtained using a handheld X-ray unit. Therefore, clinicians can apply these filters based on personal preference without compromising diagnostic reliability.

摘要

目的

评估增强滤过器对使用手持式X射线设备获取的X线片上邻面龋损诊断的影响。

方法

使用配置为2.5 mA、60 kVp和0.45秒曝光时间的Eagle X射线手持式设备(Alliage,巴西圣保罗),获取40颗出现白斑或牙釉质变色的人类牙齿的X线片。使用两种数字成像系统(VistaScan和Digora Toto)进行X线片采集。总共12种增强滤过器(每个系统各有6种)应用于这些X线片。5名对滤过条件不知情的口腔颌面放射科医生使用5分制独立评估X线片上是否存在龋损。根据检查者的反应确定受试者工作特征曲线下面积、敏感度和特异度,并使用单因素方差分析对所测试的滤过器进行比较,显著性水平为5%。加权Kappa指数用于评估检查者在邻面龋损诊断中的内部和相互一致性。

结果

应用所测试的增强滤过器对使用手持式X射线设备获取的X线片上邻面龋损的诊断指标没有影响(p>0.05)。虽然检查者内部一致性较高,但检查者之间的一致性从中度到良好不等。

结论

VistaScan和Digora Toto数字系统中可用的增强滤过器不会影响使用手持式X射线设备获取的X线片上邻面龋损的诊断准确性。因此,临床医生可以根据个人偏好应用这些滤过器,而不会影响诊断可靠性。