Oliveira-Santos Nicolly, Gaêta-Araujo Hugo, Ruiz Débora Costa, Nascimento Eduarda Helena Leandro, Cral Wilson Gustavo, Oliveira-Santos Christiano, Groppo Francisco Carlos
Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, 13414-903, Brazil.
School of Dentistry, Federal University of Alfenas (UNIFAL-MG), Alfenas, Minas Gerais, Brazil.
Clin Oral Investig. 2022 Jul;26(7):4743-4752. doi: 10.1007/s00784-022-04438-5. Epub 2022 Mar 10.
To evaluate the influence of digital filters of intraoral radiographic systems on the diagnosis of simulated internal and external root resorptions and image quality.
Internal root resorption (IRR) and external root resorption (ERR) were simulated in 34 teeth. For image acquisition, two radiographic systems were used: Digora Toto and VistaScan. All filters available in these systems were applied. Three observers scored the detection of root resorptions in a 5-point scale. The noise and the contrast-to-noise ratio (CNR) were calculated. The area under ROC curve, sensitivity, specificity, and accuracy were obtained. One-way ANOVA with Tukey's post hoc tests compared the diagnostic values, noise, and CNR between the filters (α = 0.05).
For ERR, there were no significant differences in diagnostic values between the filters tested for both systems. For IRR, Original and Noise Reduction filters presented higher sensitivity than the Sharpen2 filter for images from Digora Toto, with no differences between the other groups. For VistaScan, there were no significant differences of diagnostic values between the groups studied. Noise values differed among the filters of both systems. The CNR of the filters differed only for the bone region for Digora Toto, while for VistaScan, both tooth and bone regions differed.
Despite promoting changes in pixel intensities and affecting the noise level of the radiographic images, the digital filters of Digora Toto and VistaScan systems do not affect the diagnosis of internal or external root resorptions.
Digital filters are common tools in digital radiographic systems and may be used by the professional without impairment in root resorptions diagnosis.
评估口腔内放射成像系统的数字滤波器对模拟的牙根内吸收和外吸收诊断及图像质量的影响。
在34颗牙齿上模拟牙根内吸收(IRR)和外吸收(ERR)。图像采集使用两种放射成像系统:Digora Toto和VistaScan。应用这两个系统中所有可用的滤波器。三位观察者采用5分制对牙根吸收的检测进行评分。计算噪声和对比噪声比(CNR)。获得ROC曲线下面积、敏感度、特异度和准确度。采用单因素方差分析及Tukey事后检验比较各滤波器之间的诊断值、噪声和CNR(α = 0.05)。
对于ERR,两个系统所测试的滤波器之间的诊断值无显著差异。对于IRR,Digora Toto系统的图像中,原始滤波器和降噪滤波器的敏感度高于锐化2滤波器,其他组之间无差异。对于VistaScan系统,所研究的组之间诊断值无显著差异。两个系统的滤波器噪声值不同。Digora Toto系统仅在骨区域的滤波器CNR不同,而对于VistaScan系统,牙齿和骨区域均不同。
尽管Digora Toto和VistaScan系统的数字滤波器会引起像素强度变化并影响放射图像的噪声水平,但不会影响牙根内吸收或外吸收的诊断。
数字滤波器是数字放射成像系统中的常用工具,专业人员使用时不会损害牙根吸收的诊断。