Saha Anish Kumar, Bodhey Narendra Kuber, Kashyap Nitin Kumar, Rathore Vinay, Badge Rohit Paras, Aggarwal Jyoti, Pathak Naman Mahesh
Department of Nephrology, All India Institute of Medical Sciences, Raipur, Tatibandh, Chhattisgarh, India.
Department of Radiodiagnosis, All India Institute of Medical Sciences, Raipur, Tatibandh, Chhattisgarh, India.
Indian J Nephrol. 2025 May-Jun;35(3):425-426. doi: 10.25259/IJN_53_2024. Epub 2024 May 18.
The procedure of tunnelled hemodialysis catheter insertion is generally considered safe. We report the case of a lady who had a malpositioned femoral tunneled hemodialysis catheter that entered into the spinal canal causing neurological weakness. The catheter was later safely removed leading to partial neurological recovery.
隧道式血液透析导管插入术通常被认为是安全的。我们报告了一例女性患者,其股部隧道式血液透析导管位置不当,进入了椎管,导致神经功能障碍。该导管后来被安全移除,患者神经功能部分恢复。