Optima™ 线圈系统在颅内动脉瘤治疗中的初步经验:从脑动脉角度看手术及介入治疗的安全性和有效性

Initial experiences of the Optima™ coil system in intracranial aneurysm treatment: surgical and interventional approach to safety and efficacy in terms of cerebral arteries.

作者信息

Ulusoy Bekir Sıtkı Said, Altay Çetin Murat, Onay Mehmet, Binboga Ali Burak, Kaya Murat

机构信息

University of Health Sciences - Gaziantep City Hospital - Department of Interventional Radiology - Gaziantep - Turkey.

出版信息

Acta Cir Bras. 2025 May 9;40:e403425. doi: 10.1590/acb403425. eCollection 2025.

Abstract

PURPOSE

To evaluate the angiographic outcomes of the Optima™ coil system in the endovascular treatment of saccular intracranial aneurysms to present real-world experiences.

METHODS

The study encompassed patients with both ruptured and unruptured aneurysms who underwent treatment with the Optima™ coil system. A retrospective analysis was conducted to examine patient and aneurysm characteristics, complication rates, and angiographic outcomes.

RESULTS

The total of 326 Optima™ coil implantations was performed in 64 aneurysms, with a mean maximum diameter of 7.49 ± 3.08 mm (range: 2.5-16.5 mm), among 64 patients (37 females and 27 males, mean age: 53.34 ± 14 years old). The average number of implanted coils was 5.06 ± 1.73. The mean packing density was 26.2% (range = 19.2-34.6), observed to be significantly higher in aneurysms with complete occlusion and neck remnants compared to those with a residual dome (p < 0.01). The mean follow-up period was 15.9 ± 8.1 months. One case (1.5%) reported a coil malfunction attributed to coil stretching. The mortality rate was 3.1% (n = 2).

CONCLUSION

The Optima™ coil system exhibited safety and efficacy in the endovascular treatment of both ruptured and unruptured intracranial aneurysms, demonstrating favorable angiographic outcomes. Nevertheless, further studies are necessary to validate these results over the long term.

摘要

目的

评估Optima™线圈系统在颅内囊状动脉瘤血管内治疗中的血管造影结果,以呈现真实世界的经验。

方法

该研究纳入了使用Optima™线圈系统进行治疗的破裂和未破裂动脉瘤患者。进行回顾性分析以检查患者和动脉瘤特征、并发症发生率及血管造影结果。

结果

64例患者(37例女性和27例男性,平均年龄:53.34±14岁)的64个动脉瘤共进行了326次Optima™线圈植入,动脉瘤平均最大直径为7.49±3.08mm(范围:2.5 - 16.5mm)。平均植入线圈数量为5.06±1.73。平均填充密度为26.2%(范围 = 19.2 - 34.6),观察到完全闭塞和有颈部残留的动脉瘤的填充密度显著高于有残留瘤顶的动脉瘤(p < 0.01)。平均随访期为15.9±8.1个月。1例(1.5%)报告因线圈拉伸导致线圈故障。死亡率为3.1%(n = 2)。

结论

Optima™线圈系统在破裂和未破裂颅内动脉瘤的血管内治疗中显示出安全性和有效性,并呈现出良好的血管造影结果。然而仍需要进一步研究以长期验证这些结果。